Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath-hold.
نویسندگان
چکیده
PURPOSE To develop a saturation recovery myocardial T1 mapping method for the simultaneous multislice acquisition of three slices. METHODS Saturation pulse-prepared heart rate independent inversion recovery (SAPPHIRE) T1 mapping was implemented with simultaneous multislice imaging using FLASH readouts for faster coverage of the myocardium. Controlled aliasing in parallel imaging (CAIPI) was used to achieve minimal noise amplification in three slices. Multiband reconstruction was performed using three linear reconstruction methods: Slice- and in-plane GRAPPA, CG-SENSE, and Tikhonov-regularized CG-SENSE. Accuracy, spatial variability, and interslice leakage were compared with single-band T1 mapping in a phantom and in six healthy subjects. RESULTS Multiband phantom T1 times showed good agreement with single-band T1 mapping for all three reconstruction methods (normalized root mean square error <1.0%). The increase in spatial variability compared with single-band imaging was lowest for GRAPPA (1.29-fold), with higher penalties for Tikhonov-regularized CG-SENSE (1.47-fold) and CG-SENSE (1.52-fold). In vivo multiband T1 times showed no significant difference compared with single-band (T1 time ± intersegmental variability: single-band, 1580 ± 119 ms; GRAPPA, 1572 ± 145 ms; CG-SENSE, 1579 ± 159 ms; Tikhonov, 1586 ± 150 ms [analysis of variance; P = 0.86]). Interslice leakage was smallest for GRAPPA (5.4%) and higher for CG-SENSE (6.2%) and Tikhonov-regularized CG-SENSE (7.9%). CONCLUSION Multiband accelerated myocardial T1 mapping demonstrated the potential for single-breath-hold T1 quantification in 16 American Heart Association segments over three slices. A 1.2- to 1.4-fold higher in vivo spatial variability was observed, where GRAPPA-based reconstruction showed the highest homogeneity and the least interslice leakage. Magn Reson Med 78:462-471, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
منابع مشابه
Joint myocardial T1 and T2 mapping using a combination of saturation recovery and T2 -preparation.
PURPOSE To develop a heart-rate independent breath-held joint T1 -T2 mapping sequence for accurate simultaneous estimation of coregistered myocardial T1 and T2 maps. METHODS A novel preparation scheme combining both a saturation pulse and T2 -preparation in a single R-R interval is introduced. The time between these two pulses, as well as the duration of the T2 -preparation is varied in each ...
متن کاملHigh-resolution myocardial T1 mapping using single-shot inversion recovery fast low-angle shot MRI with radial undersampling and iterative reconstruction
OBJECTIVE To develop a novel method for rapid myocardial T1 mapping at high spatial resolution. METHODS The proposed strategy represents a single-shot inversion recovery experiment triggered to early diastole during a brief breath-hold. The measurement combines an adiabatic inversion pulse with a real-time readout by highly undersampled radial FLASH, iterative image reconstruction and T1 fitt...
متن کاملModified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart.
A novel pulse sequence scheme is presented that allows the measurement and mapping of myocardial T1 in vivo on a 1.5 Tesla MR system within a single breath-hold. Two major modifications of conventional Look-Locker (LL) imaging are introduced: 1) selective data acquisition, and 2) merging of data from multiple LL experiments into one data set. Each modified LL inversion recovery (MOLLI) study co...
متن کاملSaturated double-angle method for rapid B1+ mapping.
For in vivo magnetic resonance imaging at high field (> or =3 T) it is essential to consider the homogeneity of the active B(1) field (B(1)+), particularly if surface coils are used for RF transmission. A new method is presented for highly rapid B(1)+ magnitude mapping. It combines the double angle method with a B(1)-insensitive magnetization-reset sequence such that the choice of repetition ti...
متن کاملFree-breathing multislice native myocardial T1 mapping using the slice-interleaved T1 (STONE) sequence.
PURPOSE To develop a novel pulse sequence for free-breathing, multislice, native myocardial T1 mapping. METHODS The slice-interleaved T1 (STONE) sequence consists of multiple sets of single-shot images of different slices, acquired after a single nonselective inversion pulse. Each slice is only selectively excited once after each inversion pulse to allow sampling of the unperturbed longitudin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 78 2 شماره
صفحات -
تاریخ انتشار 2017