New fast screening method for organochlorine pesticides in water by using solid-phase microextraction with fast gas chromatography and a pulsed-discharge electron capture detector
نویسندگان
چکیده
A new fast screening method has been developed for the analysis of organochlorine pesticides in water that takes less than 10 min to perform and has detection limits of the order of 10 ng l21. Pesticide extraction was achieved by solid-phase microextraction and the separation was performed using a micro-bore (0.1 mm) capillary column. A laboratory-built cryotrap system was used to focus the analytes prior to introduction to the column and a pulsed-discharge electron capture detector enabled sensitive, selective measurements of the pesticide peaks to be made. The 100 mm polydimethylsilicone (PDMS) coated fibre gave better recoveries than the 30 or 7 mm film PDMS fibres and an inter-fibre study comparing three 100 mm film fibres showed good reproducibility. With extraction times of 2 min, the procedure was found to be linear over the range 0.01–1.2 ng ml21. The procedure was tested with a real river water sample.
منابع مشابه
Fast gas chromatography of explosive compounds using a pulsed-discharge electron capture detector.
The detection of a mixture of nine explosive compounds, including nitrate esters, nitroaromatics, and a nitramine in less than 140 sec is described. The new method employs a commercially available pulsed-discharge electron capture detector (PDECD) coupled with a microbore capillary gas chromatography (GC) column in a standard GC oven to achieve on-column detection limits between 5 and 72 fg for...
متن کاملDetermination of Selected Pesticide Residues from Gilgel Gibe (I) Hydroelectric Dam Reservoir and Its Tributaries, Jimma Zone, Ethiopia
In this study, the level of selected organophosphorus and organochlorine pesticide residues from water samples of Gilgle Gibe (I) hydroelectric dam reservoir and its potential tributaries, Jimma zone, Ethiopia, was determined by gas chromatography-electron capture detector (GC-ECD). Low density based dispersive liquid-liquid microextraction (LD-DLLME) using toluene (as extractant) and acetonitr...
متن کاملAccumulation and distribution of persistent organochlorine pesticides and their contamination of surface water and sediments of the Sabarmati River, India
Pesticides are chemical substances used to control pests in an effort to increase crop production and quality, and food storage. The levels of pesticides in different environmental compartments, such as water, soil, agricultural foods, and products of animal origin, have become a relevant issue. In this study, the levels of pesticide residues in Sabarmati River of Gujarat, India, have been inve...
متن کاملON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER
An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...
متن کاملOrdered Nanoporous Carbon Based Solid-Phase Microextraction for the Analysis of Nitroaromatic Compounds in Aqueous Samples
In this paper, the possibility of using a new ordered nanoporous carbon as a new fiber in headspace solid phase microextraction (HS-SPME) to determine of mononitrotoluenes (MNTs) in waste water is demonstrated. The structural order and textural properties of the ordered nanoporous carbon were studied by X Ray Diffraction (XRD), Scanning Electron Microscopy (SEM) images and nitrogen adsorpti...
متن کامل