Piping Fragility Composed of Different Materials by Using OpenSees Software

نویسندگان

  • Woo Young Jung
  • Min Ho
  • Bu Seog Ju
چکیده

A failure of the non-structural component can cause significant damages in critical facilities such as nuclear power plants and hospitals. Historically, it was reported that the damage from the leakage of sprinkler systems, resulted in the shutdown of hospitals for several weeks by the 1971 San Fernando and 1994 North Ridge earthquakes. In most cases, water leakages were observed at the cross joints, sprinkler heads, and T-joint connections in piping systems during and after the seismic events. Hence, the primary objective of this study was to understand the seismic performance of T-joint connections and to develop an analytical Finite Element (FE) model for the T-joint systems of 2-inch fire protection piping system in hospitals subjected to seismic ground motions. In order to evaluate the FE models of the piping systems using OpenSees, two types of materials were used: 1) Steel02 materials and 2) Pinching4 materials. Results of the current study revealed that the nonlinear moment-rotation FE models for the threaded T-joint reconciled well with the experimental results in both FE material models. However, the system-level fragility determined from multiple nonlinear time history analyses at the threaded T-joint was slightly different. The system-level fragility at the T-joint, determined by Pinching4 material was more conservative than that of using Steel02 material in the piping system. Keywords— Fragility, T-joint, Piping, Leakage, Sprinkler.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic fragility assessment of RC moment resisting frame buildings designed for different editions of Iranian seismic design code

Background and objective: Developing fragility and vulnerability functions are important tools in seismic reliability assessment of buildings and are widely used in regional seismic risk studies. To date sufficient studies for developing analytical fragility functions for Iranian code-conforming buildings have not been carried out. Performing such studies are necessary to assess the adequacy of...

متن کامل

Estimating piping around bridge piers using the SSIIM software

Estimating maximum scour depth is normally required in order to determine the depth of  bridge piles. The present paper uses the SSIIM Software which considers flow and sediment equations in a three dimensional manner. The software models flow field around circular bridge pile by resolving Navier-Stokes three-dimensional equations and k-  method, and by temporary solution of flow field and cont...

متن کامل

SEISMIC PERFORMANCE OF CROSS-SHAPED COLUMNS WITH 500 MPa GRADE REINFORCING STEEL BARS

Original scientific paper Based on the experimental research on three cross-shaped columns with 500 MPa grade reinforcing steel bars, the contrastive analysis is made on failure mode, bearing capacity and displacement ductility of each column specimens with different stirrup spacing under the identical axial compression ratio. The research shows that the longitudinal bars yield before spalling ...

متن کامل

Modeling fluid–structure interaction by the particle finite element method in OpenSees

The OpenSees finite element software framework is extended for simulating fluid–structure interaction (FSI) by the particle finite element method (PFEM). At high levels of the framework, new classes handle meshing and interface detection of the fluid and structure domains and implement the fractional step method in order to solve the governing equations of linear momentum and mass conservation....

متن کامل

Assessment of Structure-Specific Fragility Curves for Soft Storey Buildings Implementing IDA and SPO Approaches

Soft storey building is popular due to the functional and aesthetic purpose, despite its weakness in resisting seismic excitation. Nonlinear Static (Pushover) Analysis (POA) is a time saving and simple assessment procedure prosposed in Eurocode 8 (EC8). However, its reliability in designing structure still remains a question. At the first stage, seismic performance of several building models us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014