Evaluation of the Efficacy of Methyl Bromide in the Decontamination of Building and Interior Materials Contaminated with Bacillus anthracis Spores

نویسندگان

  • Joseph P Wood
  • Morgan Wendling
  • William Richter
  • Andrew Lastivka
  • Leroy Mickelsen
چکیده

The primary goal of this study was to determine the conditions required for the effective inactivation of Bacillus anthracis spores on materials by using methyl bromide (MeBr) gas. Another objective was to obtain comparative decontamination efficacy data with three avirulent microorganisms to assess their potential for use as surrogates for B. anthracis Ames. Decontamination tests were conducted with spores of B. anthracis Ames and Geobacillus stearothermophilus, B. anthracis NNR1Δ1, and B. anthracis Sterne inoculated onto six different materials. Experimental variables included temperature, relative humidity (RH), MeBr concentration, and contact time. MeBr was found to be an effective decontaminant under a number of conditions. This study highlights the important role that RH has when fumigation is performed with MeBr. There were no tests in which a ≥6-log10 reduction (LR) of B. anthracis Ames was achieved on all materials when fumigation was done at 45% RH. At 75% RH, an increase in the temperature, the MeBr concentration, or contact time generally improved the efficacy of fumigation with MeBr. This study provides new information for the effective use of MeBr at temperatures and RH levels lower than those that have been recommended previously. The study also provides data to assist with the selection of an avirulent surrogate for B. anthracis Ames spores when additional tests with MeBr are conducted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Whole‐building decontamination of Bacillus anthracis Sterne spores by methyl bromide fumigation

AIMS To evaluate the field inactivation of Bacillus anthracis Sterne spores with methyl bromide (MB) using commercial fumigation techniques. METHODS AND RESULTS Eighty-seven wood and 87 glass coupons each containing ca. 1 × 10(6) B. anthracis Sterne spores, were placed in 22 locations inside a 1444 m(3) conference building. Four additional 12-coupon sets (six wood, six glass) were removed fro...

متن کامل

Systematic evaluation of the efficacy of chlorine dioxide in decontamination of building interior surfaces contaminated with anthrax spores.

Efficacy of chlorine dioxide (CD) gas generated by two distinct generation systems, Sabre (wet system with gas generated in water) and ClorDiSys (dry system with gas generated in air), was evaluated for inactivation of Bacillus anthracis spores on six building interior surfaces. The six building materials included carpet, acoustic ceiling tile, unpainted cinder block, painted I-beam steel, pain...

متن کامل

Evaluation the Efficacy of Anthrax Vaccine against Challenge with a Highly Virulent Strain of Bacillus anthracis Isolated from Soil in Sheep, Goats and Guinea Pigs in Iran

  Protection of animals immunized against Bacillus anthracis is usually demonstrated by challenging with an appropriate dose of a strain of Bacillus anthracis that is lethal to unvaccinated animals inoculated at the same time. In this study the protective efficacy in anthrax vaccine (34F2 sterne strain spore) was evaluated in sheep, goats and guinea pigs challenged with subcutaneous inoculation...

متن کامل

A Novel Approach for Conducting Room-scale Vaporous Hydrogen Peroxide Decontamination of Virulent Bacillus anthracis Spores

Studies have been conducted to determine the efficacy of various decontamination technologies against virulent B. anthracis and surrogate spores within small, bench-scale chambers. This study assessed an approach for evaluating room-scale (~2,700 ft3) decontamination efficacy of vaporous hydrogen peroxide fumigation against B. anthracis Ames and B. subtilis spores deposited onto porous and non-...

متن کامل

Decontamination Efficacy of Three Commercial-Off-The-Shelf (COTS) Sporicidal Disinfectants on Medium-Sized Panels Contaminated with Surrogate Spores of Bacillus anthracis

In the event of a wide area release and contamination of a biological agent in an outdoor environment and to building exteriors, decontamination is likely to consume the Nation's remediation capacity, requiring years to cleanup, and leading to incalculable economic losses. This is in part due to scant body of efficacy data on surface areas larger than those studied in a typical laboratory (5×10...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2016