A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis.

نویسندگان

  • Michael Bottlang
  • Josef Doornink
  • Gregory D Byrd
  • Daniel C Fitzpatrick
  • Steven M Madey
چکیده

BACKGROUND Locking plates transmit load through fixed-angle locking screws instead of relying on plate-to-bone compression. Therefore, locking screws may induce higher stress at the screw-bone interface than that seen with conventional nonlocked plating. This study investigated whether locked plating in osteoporotic diaphyseal bone causes a greater periprosthetic fracture risk than conventional plating because of stress concentrations at the plate end. It further investigated the effect of replacing the locked end screw with a conventional screw on the strength of the fixation construct. METHODS Three different bridge-plate constructs were applied to a validated surrogate of the osteoporotic femoral diaphysis. Constructs were tested dynamically to failure in bending, torsion, and axial loading to determine failure loads and failure modes. A locked plating construct was compared with a nonlocked conventional plating construct. Subsequently, the outermost locking screw in locked plating constructs was replaced with a conventional screw to reduce stress concentrations at the plate end. RESULTS Compared with the conventional plating construct, the locked plating construct was 22% weaker in bending (p = 0.013), comparably strong in torsion (p = 0.05), and 15% stronger in axial compression (p = 0.017). Substituting the locked end screw with a conventional screw increased the construct strength by 40% in bending (p = 0.001) but had no significant effect on construct strength under torsion (p = 0.22) and compressive loading (p = 0.53) compared with the locked plating construct. Under bending, all constructs failed by periprosthetic fracture. CONCLUSIONS Under bending loads, the focused load transfer of locking plates through fixed-angle screws can increase the periprosthetic fracture risk in the osteoporotic diaphysis compared with conventional plates. Replacing the outermost locking screw with a conventional screw reduced the stress concentration at the plate end and significantly increased the bending strength of the plating construct compared with an all-locked construct (p = 0.001).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength.

BACKGROUND Several strategies to reduce construct stiffness have been proposed to promote secondary bone healing following fracture fixation with locked bridge plating constructs. However, stiffness reduction is typically gained at the cost of construct strength. In the present study, we tested whether a novel strategy for stiffness reduction, termed far cortical locking, can significantly redu...

متن کامل

Font: Times New Roman 10pt THE TITLE SHOULD BE IN ALL CAPITAL LETTERS AND AS CONCISE AS POSSIBLE

RATIONALE: The purpose of the current study is to establish the biomechanical rationale for the increased risk of periprosthetic fracture associated with locking screw constructs over conventional screw constructs. This is important because the promise of locking plates to increase fixation in osteoporotic bone must be balanced with the potential complication of a periprosthetic fracture. An un...

متن کامل

Locked Plating in Practice: Indications and Current Concepts

Why use a locked plate? The increasing use of locked plates in fracture care has raised concern that the appropriate usage of these plates is being lost with lack of adherence to some of the basic principles of fracture fixation. The development of locking plate technology has introduced a new and exciting dimension to fracture fixation but they should be applied with specific intent and indica...

متن کامل

Biomechanics of locked plates and screws.

OBJECTIVE To review the biomechanical principles that guide fracture fixation with plates and screws; specifically to compare and contrast the function and roles of conventional unlocked plates to locked plates in fracture fixation. We review basic plate and screw function, discuss the design rationale for the new implants, and examine the biomechanical evidence that supports the use of such im...

متن کامل

Locked plate fixation of the comminuted distal fibula: a biomechanical study.

BACKGROUND The purpose of this study was to compare the biomechanical properties of locked versus nonlocked lateral fibular bridge plating of comminuted, unstable ankle fractures in a mode of catastrophic failure. METHODS We created comminuted Weber C fractures in 8 paired limbs from fresh cadavers. Fractures were plated with either standard or locked one-third tubular bridge plating techniqu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 91 3  شماره 

صفحات  -

تاریخ انتشار 2009