High defibrillation threshold in patients with implantable defibrillator: how effective is the subcutaneous finger lead?
نویسندگان
چکیده
OBJECTIVE Even in the era of high output implantable cardioverter defibrillator (ICD) devices, a certain proportion of patients cannot be successfully defibrillated with 10 J safety margin. In practice, either the use of a single- or double-coil lead does not guarantee successful termination of induced ventricular fibrillation. Therefore, we investigated the effectiveness of the subcutaneous finger lead placed at the subcutaneous tissue dorsal to the left ventricle in terms of defibrillation threshold (DFT) lowering. METHODS Two thousand, eight hundred and three consecutive, unselected patients underwent first-time ICD implantation or ICD device exchange from 6/1999 through 3/2007. The mean age of the patients was 65.4 years. A total of 79.3% of the patients were male. The only implanted subcutaneous lead was the 6996 model by Medtronic Inc. RESULTS One hundred and seventy-seven patients (6.3%) received a subcutaneous finger lead implantation. According to the current institutional DFT testing protocol, any failure of the two standard DFT tests in first-time ICD implantation or a failure at the single test in ICD exchange operations was the trigger for subcutaneous finger lead implantation. The proportion of subcutaneous finger lead implantations increased parallel to a markedly larger amount of implantations. Since high output devices became standard, the implantation number of subcutaneous finger leads decreases. The mean of unsuccessful DFTs prior to subcutaneous finger lead implantation was 27.2+/-5.3 J. After subcutaneous finger lead implantation, the mean successful DFT was 17.9+/-3.3 J. No complication due to subcutaneous finger lead implantation occurred. CONCLUSION The subcutaneous finger lead is a quick, safe and effective method for DFT lowering.
منابع مشابه
Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement
Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.
متن کاملImplantation of additional defibrillation lead into the coronary sinus: an effective method of decreasing defibrillation threshold.
We report a case of successful implantation of an additional defibrillation lead into the coronary sinus due to high defibrillation threshold (DFT) in a seriously ill patient with a history of extensive myocardial infarction referred for implantable cardioverter- defibrillator implantation after an episode of unstable ventricular tachycardia. All previous attempts to reduce DFT, including subcu...
متن کاملSuccessful intermuscular implantation of subcutaneous implantable cardioverter defibrillator in a Japanese patient with pectus excavatum
The entirely subcutaneous implantable cardioverter-defibrillator (ICD) system was developed to provide a life-saving defibrillation therapy that does not affect the heart and vasculature. The subcutaneous ICD is preferred over the transvenous ICD for patients with a history of recurrent infection presenting major life-threatening rhythms. In this case report, we describe the first successful in...
متن کاملA permanent transvenous lead system for an implantable pacemaker cardioverter-defibrillator. Nonthoracotomy approach to implantation.
A transvenous lead system for implantable defibrillators would obviate a surgical thoracotomy and reduce the morbidity and mortality associated with implantation. We evaluated the clinical performance of a new nonthoracotomy lead system that included a defibrillation lead in the coronary sinus. At the time of defibrillator implantation, transvenous defibrillation leads were inserted percutaneou...
متن کاملSubcutaneous ICD lead position affects defibrillation threshold
Introduction Subcutaneous implantable cardioverter-defibrillators (S-ICD) provide an alternative to traditional transvenous implantable cardioverter-defibrillators (TV-ICD) and avoid complications associated with intravascular access and leads. They are highly effective in detecting and treating ventricular arrhythmias, with comparable inappropriate shock rates. Use of S-ICD is anticipated to i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 35 3 شماره
صفحات -
تاریخ انتشار 2009