The semicolon sign: dopamine transporter imaging artifact from head tilt.

نویسندگان

  • Matthew F Covington
  • Natalie A McMillan
  • Ryan J Avery
  • Phillip H Kuo
چکیده

Dopamine transporter (DAT) imaging is a valuable tool to aid in the diagnosis of Parkinson disease and other Parkinsonian syndromes. DAT imaging is special among clinical nuclear medicine scans in that the already small caudate and putamen are presented in multiple thin axial cuts. Because the imaged basal ganglia are small, slight differences in head tilt may result in a significant artifact that we have termed the semicolon sign. The semicolon sign occurs when forward head tilt creates select images that show the caudate nuclei separate from the putamen. This gives the false impression that DAT activity in the putamen is decreased or absent. To avoid falsely attributing this artifact to loss of putaminal activity, it is imperative that the interpreting physician first recognize the artifact and then mentally integrate all provided images to identify normal activity in the putamen on subsequent levels. Furthermore, quantitative software packages for automated DAT scan interpretation are now available. If images demonstrating the semicolon sign are used for automated interpretation, loss of activity in the putamen may be falsely calculated, thereby contributing to erroneous results. Quality control measures are essential to ensure that technologists correctly position each patient's head to minimize head tilt artifact on DAT scan images. A protocol to obtain optimal head positioning is presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The pinwheel sign: artifact from head rotation during SPECT acquisition for dopamine transporter imaging.

This case study illustrates the pattern and significance of the pinwheel sign, a SPECT artifact from rotational head motion that can complicate the diagnosis of Parkinson disease. Monitoring the patient during image acquisition is crucial since rotational motion artifacts are difficult to identify on raw or processed images and may lead to incorrect interpretation of findings.

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Evaluation of VNTR polymorphisms of dopamine transporter gene and the risk of bipolar disorder in Zahedan, southeast Iran

The exact role of dopamine transporter gene (DAT1) in the pathogenesis of bipolar disorder type 1 (BD) is not understood. In the present study, we aimed to evaluate the possible association between 30, 40 and 63 bp variable number tandem repeat (VNTR) polymorphisms of DAT1 gene and the risk of type 1 (BD) in a sample of Iranian population. This case-control study was performed on 152 BD patient...

متن کامل

Correlation of striatal dopamine transporter imaging with post mortem substantia nigra cell counts.

Dopamine transporter imaging is widely used for the differential diagnosis of parkinsonism. Only limited data are available on the relationship between striatal dopamine transporter binding and dopaminergic cell loss in the substantia nigra (SN). We analyzed postmortem SN cell counts in patients who had previously undergone dopamine transporter single-photon emission computed tomography (SPECT)...

متن کامل

The truncation artifact in a skinny patient following myocardial perfusion SPECT

Myocardial perfusion SPECT is one of the most common imaging techniques performed in nuclear medicine departments. To avoid misleading interpretation, it is necessary to address the quality control and technical problems. The truncation artifact occurs when the patient size is large relative to the field of view of the camera, causing false perfusion defects in the LV myocardium, misinterpreted...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 2013