Gravity Reduction View: A Radiographic Technique for the Evaluation and Management of Weber B Fibula Fractures.
نویسندگان
چکیده
BACKGROUND While various radiographic parameters and application of manual/gravity stress have been proposed to elucidate instability for Weber B fibula fractures, the prognostic capability of these modalities remains unclear. Determination of anatomic positioning of the mortise is paramount. We propose a radiographic technique, the Gravity Reduction View (GRV), which helps elucidate non-anatomic positioning and reducibility of the mortise. METHODS The patient is positioned lateral decubitus with the injured leg elevated on a holder with the fibula directed superiorly. The x-ray cassette is placed posterior to the heel, with the beam angled at 15° of internal rotation to obtain a mortise view. Our proposed treatment algorithm is based upon the measurement of the medial clear space (MCS) on the GRV versus the static mortise view (and in comparison to the superior clear space (SCS)) and is based on reducibility of the MCS. A retrospective review of patients evaluated utilizing the GRV was performed. RESULTS 26 patients with Weber B fibula fractures were managed according to this treatment algorithm. Mean age was 50.57 years old (range:18-81, SD=19). 17 patients underwent operative treatment and 9 patients were initially treated nonoperatively. 2 patients demonstrated late displacement and were treated surgically. Using this algorithm, at a mean follow-up of 26 weeks, all patients had a final MCS that was less than the SCS (final mean MCS 2.86 mm vs. mean SCS of 3.32) indicating effectiveness of the treatment algorithm. CONCLUSIONS The GRV is a radiographic view in which deltoid competency, reducibility and initial positioning of the mortise are assessed by comparing a static mortise view with the appearance of the mortise on the GRV. We have proposed a treatment algorithm based on the GRV that we found it useful in our patients in guiding treatment and achieving anatomic mortise alignment.
منابع مشابه
Gravity Reduction View: A Radiographic Technique for the Evaluation and Management of Weber B Fibula Fractures
Background: While various radiographic parameters and application of manual/gravity stress have been proposed to elucidate instability for Weber B fibula fractures, the prognostic capability of these modalities remains unclear. Determination of anatomic positioning of the mortise is paramount. We propose a novel view, the Gravity Reduction View (GRV), which helps elucidate non-anatomic position...
متن کاملMinimally Invasive Surgical Approach to Distal Fibula Fractures: A Technique Tip
Wound complications following ankle fracture surgery are a major concern. Through the use of minimally invasive surgical techniques some of these complications can be mitigated. Recent investigations have reported on percutaneous fixation of distal fibula fractures demonstrating similar radiographic and functional outcomes to traditional open approaches. The purpose of this manuscript is to ...
متن کاملComparison of three plate system for lateral malleolar fixation
BACKGROUND This study was to compare clinical and radiographic outcomes with three different implants and evaluate the effectiveness of minimally invasive plate osteosynthesis (MIPO) technique for the distal fibular fractures. METHODS We performed a retrospective cohort single-surgical team single-facility study between 2000 and 2011. 147 patients receiving surgical interventions for closed, ...
متن کاملRadiographic and Ultrasonographic Findings of Some Fetlock Disorders in Donkeys
Objective- To describe the radiographic and ultrasonographic changes in the fetlock disorders indonkeys. Design- Descriptive study. Animals- - Twenty nine donkeys with clinical, radiographic and ultrasonographic evidences of fetlock disorders and lameness were used in this study. Procedures- Clinical, radiographic and ultrasonographic studies for donkeys have fetlock disorders and lameness were...
متن کاملOutcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia
Background: Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The archives of bone and joint surgery
دوره 5 2 شماره
صفحات -
تاریخ انتشار 2017