Validation test for climate control on air-loss supports.

نویسندگان

  • S I Reger
  • T C Adams
  • J A Maklebust
  • V Sahgal
چکیده

OBJECTIVE To develop a simple, reproducible validation test protocol for classification of air-loss support systems. DESIGN Simultaneous experimental measurement of moisture loss and temperature reduction at the air-loss support surface-human body equivalent interface from a sweating human skin analogue. SETTING A hospital department of physical medicine and rehabilitation. OTHER PARTICIPANTS These 3 manufacturers contributed 14 support surfaces. INTERVENTIONS Test support surfaces and a standard foam mattress were placed on a hospital bed. Water was circulated to a loading gauge, placed on a dry moisture reservoir, and connected to a water bath to keep the interface at 37 degrees +/- 0.5 degrees C. The loading gauge and support surface was adjusted 23cm below the water bath level and the air flow through the interface initiated. After the dry moisture reservoir came to temperature equilibrium for 30 minutes, it was replaced with a wet one that was saturated with 36g of saline. The temperature change and evaporation rate were recorded throughout a 90-minute test period. MAIN OUTCOME MEASURES Temperature of support surface interface and evaporation rate. RESULTS Clustered data from temperature reduction and standardized rate of moisture loss yielded 3 groups of support surfaces in categories of no air loss (control), low air loss (LAL), and high air loss. The mean values of the characteristic temperature reduction and rate of moisture loss differed significantly between the groups. By multiple comparisons with Bonferroni's adjustment, the group means differed significantly for average temperature reduction (p <.017) and for standardized rate of moisture loss (p =.0001). The measured temperature change at any instant of time reflected the effect of evaporation and the opposing effect of thermal conductivity. CONCLUSION Measurements of support interface climate change allowed for selective grouping of LAL surfaces according to rate of moisture evaporation and the resulting temperature reduction. Neither temperature change nor evaporation rate alone was sufficient to determine the microclimate characteristics of the support surface. Combined, these characteristics can effectively describe the performance of any LAL support system and may be used to define standards of performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of Sound Transmission Loss Measurement System for Measuring Muffler Performance

Muffler is a part of the vehicle exhaust system that absorb or reflect sound waves to reduce exhaust noise. One of the most important determinants of a muffler performance is the amount of attenuation that has on its input wave; this parameter is known as sound transmission loss. Four - mic standard test is one way to determine this parameter which is used in this paper. In this study, a test d...

متن کامل

LCCP Analysis of Energy-Saving Effect of Defaulting to Recirculated Cabin Air in EV Mobile Air Conditioning System

The climate control load is the most significant auxiliary loads present in vehicles today. The peak climate control load of an AC system in sedan can be as large as the engine input power. As the attention on vehicle energy economy is rising worldwide, the energy-saving of mobile air conditioning is becoming more and more important. Most mobile AC systems nowadays draw air from outside the veh...

متن کامل

Validation of summer temperature interpolation methods in northeastern Iran

  The basis of climatic data is measurements taken at a predetermined chronological order at air monitoring stations, so all measured values ​​of climatic elements can only be attributed to the point of measurement. Therefore, different interpolation methods can help a lot in estimating climate data in different places. The study area in this study is northeastern Iran, including the provinces...

متن کامل

Test-Driven Approach for Safety-Critical Software Development

Nowadays software control large majority of systems that humankind use. Systems that software is used widely, such as transportation, military, medicine and avionics must be safe during operation. Fail in these critical systems may cause catastrophic results (i.e. loss of human life, loss or severe damage to environment or equipment etc.). In order to avoid failure on safety critical systems or...

متن کامل

Energy use and indoor climate of conservation heating, dehumidification and adaptive ventilation for the climate control of a mediaeval church in a cold climate

Mediaeval churches hold substantial historical and cultural values, organs, altars, paintings that need to be preserved. Many of these churches have no climate control systems installed. Thus the indoor climate is mainly determined by the outdoor climate. Focus in this study is on the possibilities to improve indoor climate in originally unheated churches to prevent and protect churches from mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of physical medicine and rehabilitation

دوره 82 5  شماره 

صفحات  -

تاریخ انتشار 2001