Verifying epidural catheter placement with a revised technique.

نویسندگان

  • Pranav Bansal
  • Deepti Agarwal
  • Kumkum Gupta
چکیده

2) The catheter is primed with 2 ml of 0.9% normal saline and catheter port splashed to get rid of excess saline. Next, the catheter is raised vertically at the level of mid-scapula in a sitting patient or approximately 1 foot above the level of insertion in a laterally positioned patient. If the catheter tip is positioned epidurally the fluid column will fall in a manner similar to CVP manometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Epidural catheter placement in children: comparing a novel approach using ultrasound guidance and a standard loss-of-resistance technique.

BACKGROUND We report a prospective, randomized study to evaluate ultrasound guidance for epidural catheter placement in children 0-6 yr of age. METHODS Epidural catheters were placed at lumbar or thoracic cord levels in 64 children undergoing major surgery, using either ultrasonography or loss-of-resistance (LOR) for guidance. Using a 5-10 MHz linear ultrasound probe, the neuraxial structures...

متن کامل

Use of Imaging Agent to Determine Postoperative Indwelling Epidural Catheter Position

BACKGROUND Epidural anesthesia is widely used to provide pain relief, whether for surgical anesthesia, postoperative analgesia, treatment of chronic pain, or to facilitate painless childbirth. In many cases, however, the epidural catheter is inserted blindly and the indwelling catheter position is almost always uncertain. METHODS In this study, the loss-of-resistance technique was used and an...

متن کامل

Minimum current requirement for confirming the localization of an epiradicular catheter placement

BACKGROUND Based on the necessity to confirm the epiradicular catheter misplacement, epiradicular threshold current for the confirmation of catheter tip localization is required. METHODS Thirty-four adult patients with low extremity radiating pain were to receive epiradicular catheterization at the lumbosacral level. The epidural space was accessed percutaneously in cranial to caudal directio...

متن کامل

Confirmation of epidural catheter placement using nerve stimulation.

PURPOSE To examine the reliability of low current electrical epidural stimulation to confirm epidural catheter placement. METHODS Forty patients with epidural catheters (19G Arrow Flextip plus) already in place for post-operative pain management were studied. An adapter (Arrow-Johans ECG Adapter) was attached to the connector of the epidural catheter. The epidural catheter and adapter were fi...

متن کامل

Strategic placement of epidural catheter

Corresponding author: Jae-Hang Shim, M.D., Ph.D., Department of Anesthesiology and Pain Medicine, Hanyang University Hospital, 249-1, Gyomun-dong, Guri 471-701, Korea. Tel: 82-31-560-2390, Fax: 82-31-563-1731, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/licenses/by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Middle East journal of anaesthesiology

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2009