High-pressure liquid-chromatographic method for determination of gentamicin in plasma.
نویسندگان
چکیده
A rapid, specific method for measuring gentamicin in plasma by high-pressure liquid chromatography was developed. After deproteinization, gentamicin in the supernate was dansylated and extracted into ethyl acetate. The organic extract was chromatographed on a microparticulate reversed-phase column, which was eluted with aqueous acetonitrile. Use of the dansyl derivative enables fluorometry, for more sensitive quantitation. Various factors that could affect the assay sensitivity were investigated. With 0.2-ml plasma samples, the method can accurately measure as little as 1 mg of gentamicin per liter. We encountered no interferences from plasma supplemented with various drugs or plasma of patients who were on therapy with other drugs. This method can also separate gentamicin C1 from C1a and C2, all of which are present in various ratios in commercial dosage forms. This method is also applicable to gentamicin determination in urine.
منابع مشابه
Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 23 10 شماره
صفحات -
تاریخ انتشار 1977