High-dose antidepressants affect near-infrared spectroscopy signals: A retrospective study

نویسندگان

  • Akihiro Takamiya
  • Jinichi Hirano
  • Yuki Ebuchi
  • Satoyuki Ogino
  • Kenichi Shimegi
  • Hiroyuki Emura
  • Kyoko Yonemori
  • Akiko Shimazawa
  • Gentaro Miura
  • Ayako Hyodo
  • Sari Hyodo
  • Tunetaka Nagai
  • Madoka Funaki
  • Masako Sugihara
  • Mitsuhiro Kita
  • Bun Yamagata
  • Masaru Mimura
چکیده

BACKGROUND Recent studies have highlighted the clinical usefulness of near-infrared spectroscopy (NIRS) in psychiatry. However, the potential effects of psychotropics on NIRS signals remain unknown. METHODS We conducted a systematic chart review of 40 depressed patients who underwent NIRS scans during a verbal fluency task to clarify the relationships between psychotropic dosage and NIRS signals. The dosage of psychotropic medications was calculated using defined daily dose (DDD). We investigated the associations between the DDD of psychotropic medications and oxygenated hemoglobin (oxy-Hb) in single channel levels. LIMITATIONS Retrospective study design and small sample size are the main limitations. RESULTS Multiple regression analysis revealed that one channel in the right temporoparietal region had a significant association with antidepressant DDD controlling for age, sex, depression severity, and the DDD of antipsychotics and benzodiazepines. Moreover, high doses of antidepressants had significant effects on NIRS signals compared with low doses, in group comparisons. CONCLUSIONS The dose-dependent impact of antidepressants on NIRS signals should be taken into account when interpreting NIRS data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical Imaging of the Motor Cortex in the Brain in Order to Determine the Direction of the Hand Movements Using Functional Near-Infrared Spectroscopy (fNIRS)

Introduction: In recent years, optical imaging has attracted a lot of attention from scholars as a non- aggressive, efficient method for evaluating the activities of the motor cortex in the brain. Functional near-infrared spectroscopy (fNIRS (is a tool showing the hemodynamic changes in a cortical area of the brain according to optical principles. The present study has been de...

متن کامل

Inconsistent detection of changes in cerebral blood volume by near infrared spectroscopy in standard clinical tests.

The attractive possibility of near infrared spectroscopy (NIRS) to noninvasively assess cerebral blood volume and oxygenation is challenged by the possible interference from extracranial tissues. However, to what extent this may affect cerebral NIRS monitoring during standard clinical tests is ignored. To address this issue, 29 healthy subjects underwent a randomized sequence of three maneuvers...

متن کامل

Determination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares

The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...

متن کامل

Evidence of cognitive activity in functional near infrared spectroscopy signal

We show that functional near infrared spectroscopy signals can monitor task-related cerebral hemodynamic response. We detect periodicities in the near infared spectroscopy signals and show that the estimated periods are consistent across multiple detectors and subjects, despite the jittered periodicity of the stimuli sequence that is used in a target categorization experiment. ©2003 American So...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2017