Accurate determination of quantity of material in thin films by Rutherford backscattering spectrometry.
نویسندگان
چکیده
Ion beam analysis (IBA) is a cluster of techniques including Rutherford and non-Rutherford backscattering spectrometry and particle-induced X-ray emission (PIXE). Recently, the ability to treat multiple IBA techniques (including PIXE) self-consistently has been demonstrated. The utility of IBA for accurately depth profiling thin films is critically reviewed. As an important example of IBA, three laboratories have independently measured a silicon sample implanted with a fluence of nominally 5 × 10(15) As/cm(2) at an unprecedented absolute accuracy. Using 1.5 MeV (4)He(+) Rutherford backscattering spectrometry (RBS), each lab has demonstrated a combined standard uncertainty around 1% (coverage factor k = 1) traceable to an Sb-implanted certified reference material through the silicon electronic stopping power. The uncertainty budget shows that this accuracy is dominated by the knowledge of the electronic stopping, but that special care must also be taken to accurately determine the electronic gain of the detection system and other parameters. This RBS method is quite general and can be used routinely to accurately validate ion implanter charge collection systems, to certify SIMS standards, and for other applications. The generality of application of such methods in IBA is emphasized: if RBS and PIXE data are analysed self-consistently then the resulting depth profile inherits the accuracy and depth resolution of RBS and the sensitivity and elemental discrimination of PIXE.
منابع مشابه
Experimental determination of layers films thicknesses
The determination of particle induced x-ray emission (PIXE) cross sections and the concentration of elements in a material require the knowledge of the target sample thickness. In this aim, measurements of the thickness by three different methods have been performed. These are absorption of X-rays by a 55 Fe source, transmission of alpha particles by a 241 Am source and Rutherford backscatterin...
متن کاملCertified ion implantation fluence by high accuracy RBS.
From measurements over the last two years we have demonstrated that the charge collection system based on Faraday cups can robustly give near-1% absolute implantation fluence accuracy for our electrostatically scanned 200 kV Danfysik ion implanter, using four-point-probe mapping with a demonstrated accuracy of 2%, and accurate Rutherford backscattering spectrometry (RBS) of test implants from o...
متن کاملCompositional tailored sol-gel SiO2–TiO2 thin films: Crystallization, chemical bonding configuration, and optical properties
Thin films of SiO2–TiO2 composite oxides with various SiO2:TiO2 compositions were prepared by the sol-gel method, using tetraethylorthosilicate (TEOS) and titanium tetraisopropoxide (TTIP) as precursors. The composition, crystal structure, and chemical bonding configuration of the as-deposited and annealed SiO2–TiO2 thin films were analyzed using Rutherford backscattering spectrometry (RBS), gl...
متن کاملDetermination of the density of silicon–nitride thin films by ion-beam analytical techniques (RBS, PIXE, STIM)
This work presents the investigation of some commercially available and commonly used Si3N4 foils prepared with LPCVD technique. The density and the stoichiometry of these films were determined by Rutherford backscattering spectroscopy and profilometry, while the study of impurities was achieved with particle induced X-ray emission method. It was found that the density of the studied Si3N4 film...
متن کاملAtomic Layer Deposition of Praseodymium Aluminum Oxide for Electrical Applications
Praseodymium aluminum oxide (PAO) thin films were grown by atomic layer deposition (ALD) from a new precursor, tris(N,N′-diisopropylacetamidinato) praseodymium, (Pr(amd)3), trimethylaluminum (TMA), and water. Smooth, amorphous films having varying compositions of the general formula PrxAl2–xO3 were deposited on HF-last silicon and analyzed for physical and electrical characteristics. The films ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 84 14 شماره
صفحات -
تاریخ انتشار 2012