Constitutive modeling of porcine liver in indentation using 3D ultrasound imaging.
نویسندگان
چکیده
In this work we present an inverse finite-element modeling framework for constitutive modeling and parameter estimation of soft tissues using full-field volumetric deformation data obtained from 3D ultrasound. The finite-element model is coupled to full-field visual measurements by regularization springs attached at nodal locations. The free ends of the springs are displaced according to the locally estimated tissue motion, and the normalized potential energy stored in all springs serves as a measure of model-experiment agreement for material parameter optimization. We demonstrate good accuracy of estimated parameters and consistent convergence properties on synthetically generated data. We present constitutive model selection and parameter estimation for perfused porcine liver in indentation, and demonstrate that a quasilinear viscoelastic model with shear modulus relaxation offers good model-experiment agreement in terms of indenter displacement (0.19 mm RMS error) and tissue displacement field (0.97 mm RMS error).
منابع مشابه
Identifying a minimal rheological configuration: a tool for effective and efficient constitutive modeling of soft tissues.
We describe a modeling methodology intended as a preliminary step in the identification of appropriate constitutive frameworks for the time-dependent response of biological tissues. The modeling approach comprises a customizable rheological network of viscous and elastic elements governed by user-defined 1D constitutive relationships. The model parameters are identified by iterative nonlinear o...
متن کاملAdaptive beamforming in row-column addressed arrays for 3D ultrasound imaging
In recent years, to reduce the complexity of implementation, the use of 2D arrays with restricted row-column addressing has been considered for 3D ultrasound imaging. In this paper, two methods of adaptive beamforming based on the minimum variance method are represented in such a way that the computational load is much less than using the full adaptive beamforming method. In both proposed metho...
متن کاملElastic and viscoelastic properties of porcine subdermal fat using MRI and inverse FEA.
There is a scarcity of investigation into the mechanical properties of subdermal fat. Recently, progress has been made in the determination of subdermal stress and strain distributions. This requires accurate constitutive modelling and consideration of the subdermal tissues. This paper reports the results of a study to estimate non-linear elastic and viscoelastic properties of porcine subdermal...
متن کاملCharacterizing the Nonlinear Mechanical Response of Liver to Surgical Manipulation
Computer-aided medical technologies such as simulators for surgical training and planning require accurate representation of soft tissue behavior under large deformations. Limited datasets, and unrealistic models for soft tissues currently hinder the advancement of surgical simulation. This work identifies the nonlinear mechanical response of liver through the development of a physically-based ...
متن کاملViscoelastic Characterization of Perfused L Indentation Testing and Preliminary Model
INTRODUCTION Computer-aided medical technologies are currently restricted by the limited understanding of the mechanical response of solid abdominal organs to finite loading conditions typical of surgical manipulation [5]. This limitation is a result of the difficulty in acquiring the necessary data on whole organs. To develop a constitutive model capable of predicting complex surgical scenario...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the mechanical behavior of biomedical materials
دوره 2 2 شماره
صفحات -
تاریخ انتشار 2009