Effect of spinal anaesthesia on plasma concentrations of glutathione S-transferase.

نویسندگان

  • D C Ray
  • A G Robbins
  • A F Howie
  • G J Beckett
  • G B Drummond
چکیده

BACKGROUND Plasma glutathione S-transferase (GST) concentration measurement is a sensitive and specific index of hepatocellular injury. GST concentration increases after anaesthesia with most volatile anaesthetic agents, but not after propofol. Such increases are thought to result from reduced liver blood flow. The effect on GST concentration of spinal (subarachnoid) anaesthesia, which might also reduce liver blood flow, is not known. METHODS We studied the effects of spinal anaesthesia on GST concentrations measured by specific radioimmunoassay in 33 patients undergoing intermediate orthopaedic, general or gynaecological surgery. GST concentrations were measured before anaesthesia and 3, 6 and 24 h after induction of anaesthesia. Hypotension (systolic blood pressure <70% of pre-induction value) was rapidly corrected with i.v. ephedrine. RESULTS Mean duration of surgery was 41 min (range 11-80). No increase in GST concentration was observed at any time, but at 24 h GST concentration was significantly reduced (P<0.05). One patient in whom hypotension was not treated developed a greatly increased GST concentration at 3 h. CONCLUSION We found no association between spinal anaesthesia and disturbance of hepatocellular integrity when hypotension does not occur or is rapidly corrected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of sevoflurane anaesthesia on plasma concentrations of glutathione S-transferase.

To assess the effect of sevoflurane anaesthesia on hepatocellular integrity, we measured plasma concentrations of glutathione S-transferase (GST) before anaesthesia and 1, 3, 6 and 24 h after the end of anaesthesia in 41 healthy, Japanese patients undergoing elective, body surface surgery. Sevoflurane (approximately 1.0 MAC) was delivered in 50-66% nitrous oxide in oxygen via a circle system, w...

متن کامل

Hepatic function and indocyanine green clearance during and after prolonged anaesthesia with propofol.

We have studied the effects of propofol on hepatic function and clearance of indocyanine green (ICG) in 13 consecutive patients undergoing prolonged plastic and reconstructive surgery. Hepatic function was assessed using serum concentrations of liver-specific glutathione-S-transferase (GST). There were no significant changes in GST activity or plasma clearance of ICG throughout the study.

متن کامل

Indocyanine green clearance and hepatic function during and after prolonged anaesthesia: comparison of halothane with isoflurane.

Specific biochemical and physiological tests of liver function were used to assess 20 consecutive patients undergoing prolonged head and neck surgery with halothane or isoflurane anaesthesia. Hepatic function was assessed by measurement of serum concentrations of total bilirubin and albumin, and plasma activity of pseudocholinesterase, gamma-glutamyl transferase (GGT), aspartate transaminase (A...

متن کامل

Biological variation and the effect of fasting and halothane anesthesia on plasma glutathione S-transferase concentrations.

Using a specific RIA, we have investigated in patients and volunteers whether fasting, diminished hepatic clearance, hemoconcentration, or within-day biological variation might be responsible for the transient increases in plasma glutathione S-transferase (GST) concentration observed after anesthesia. GST concentration was measured in 44 healthy volunteers after an overnight fast and at 3, 6, a...

متن کامل

Hepatocellular integrity during and after isoflurane and halothane anaesthesia in surgical patients.

Subclinical disturbance in hepatocellular integrity, indicated by glutathione transferase Alpha (GSTA), has been associated with halothane, sevoflurane and propofol, but not with isoflurane anaesthesia. We anaesthetized 82 patients with isoflurane or halothane at 1 MAC for superficial surgery. GSTA concentration were measured with a sensitive time-resolved immunofluorometric assay in serum samp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 88 2  شماره 

صفحات  -

تاریخ انتشار 2002