Drug eluting stent induced coronary artery aneurysm repair by exclusion. Where are we headed?
نویسندگان
چکیده
We present a case of left anterior descending (LAD) coronary artery aneurysm at the site of previous stent placement 3 years previously. The patient presented with recent worsening of angina. Angiography and 64 slice CT angiography confirmed the presence of 6mm aneurysm of LAD at the site of previous stent involving the origin of diagonal, with thrombus proximal and distal to the stent. This patient was successfully managed by taking the posterior wall of the anterior descending artery while suturing the heel of the left internal mammary artery (LIMA)-LAD anastomosis. The idea was to create severe stenosis upstream to prevent distal embolisation from the site of aneurysm. The diagonal was grafted with a saphenous venous graft. Follow-up angiogram at 3 months demonstrated successful exclusion of the aneurysm and unobstructed flow through the grafts.
منابع مشابه
Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملManagement of a large coronary artery aneurysm with graft-coated stent during the acute phase of myocardial infarction
Coronary aneurysms in adults are rare clinical entities. Herein, we presented a 54-year-old man who was admitted with an acute extensive anterior myocardial infarction. The emergency coronary angiography revealed an isolated large aneurysm at the proximal segment of the left anterior descending coronary artery. The patient was successfully treated with a graft-coated stent
متن کاملTypical coronary artery aneurysm exactly within drug-eluting stent implantation region in a patient with rheumatoid arthritis
The information presented comes from a case report concerning a left anterior descending coronary artery aneurysm (CAA). The typical "zig-zag" phenomenon, developed exactly within the segment of the sirolimus-eluting stent (SES), and in the left anterior descending coronary artery (LAD). The patient had a previous history of rheumatoid arthritis. We speculated that the CAA could be related to t...
متن کاملAssociation of G22A variant of Adenosine Deaminase gene with coronary in-stent restenosis in coronary artery patients receiving drug-eluting stent
In-stent restenosis (ISR) is regarded as the main problem in the utilization of stents in the treatment of coronary artery atherosclerotic stenosis in percutaneous coronary intervention (PCI). This study investigated the possible role of the G22A variant of the Adenosine Deaminase gene (ADA) in the development of ISR. In this study, 91 patients who underwent PCI were divided into two groups of ...
متن کاملGeneration of a giant coronary artery aneurysm from an intra-plaque cavity with a ruptured fibrous cap: an observation over time through coronary angiography.
A 74-year-old man underwent coronary artery bypass graft surgery. Thirteen years later, he presented with complaints of exertional anterior chest oppression again. Computed tomography coronary angiography revealed the significant stenosis at the mid right coronary artery (RCA). In addition, a giant proximal left anterior descending (LAD) coronary artery aneurysm (CAA) was found. We did not obse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 36 1 شماره
صفحات -