Voltage sag and Harmonics Mitigation in Grid Connected WECS using UPFC in ETAP

نویسندگان

  • J. Hephzibah
  • Jose Queen
  • Senthil Kumar
چکیده

This paper demonstrates the mitigation of power quality issues in a grid connected wind energy conversion system using UPFC. The procedure to compensate the power quality issues like voltage sag and harmonics are presented. A Frame work for 25 bus test system is developed in the ETAP & load flow analysis &harmonic analysis is performed. It is observed that the UPFC is effective in compensating the power quality issues for the situation considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power Quality Enhancement in Grid Connected Wind Power System Based on Dfig Using Fuzzy Controlled Upqc

The renewable energy resources rule the world of power generation. Now-a-days wind farms are encouraged for up gradation of energy production, as the wind power is dirt free, readily available renewable alternative. The integration of wind farms with power grid leads to Power Quality (PQ) issues such as voltage sag, swell, flicker, harmonics etc. Most of the industrial and commercial loads are ...

متن کامل

Analyzing Impacts of FACTS Devices in Dealing with Short-Term and Long-Term Wind Turbine Faults

More than one hundred countries are using wind energy due to their easy implementation, cheap energy, and high energy efficiency. Implementation of FACTS devices in Wind Energy Conversion Systems (WECS) has been dramatically improved due to cooperative and accurate performance of FACTS devices. However, dealing with wind turbine faults promptly is crucial. Short-term and long-term faults may ha...

متن کامل

Control of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids

In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...

متن کامل

Operation and Control of Hybrid Fuel Cell/ Energy Storage Distributed Power Generation System during voltage Sag Conditions

This paper presents a control strategy for fuel cell/energy storage power generation system during voltage sag conditions. The hybrid DC power sources are connected to grid using power electronic converters include DC-DC converter and grid connected voltage source inverter. The power from hybrid power sources is controlled during voltage sag by designing of control strategy for DC-DC converter....

متن کامل

Operation and Control of Hybrid Fuel Cell/ Energy Storage Distributed Power Generation System during voltage Sag Conditions

This paper presents a control strategy for fuel cell/energy storage power generation system during voltage sag conditions. The hybrid DC power sources are connected to grid using power electronic converters include DC-DC converter and grid connected voltage source inverter. The power from hybrid power sources is controlled during voltage sag by designing of control strategy for DC-DC converter....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014