Noninvasive monitoring of local drug release using X-ray computed tomography: optimization and in vitro/in vivo validation.
نویسندگان
چکیده
In vivo release profiles of drug-loaded biodegradable implants were noninvasively monitored and characterized using X-ray computed tomography (CT). The imaging method was adapted and optimized to quantitatively examine the release of an active agent from a model cylindrical PLGA device (the millirod) into rabbit livers over 48 h. Iohexol, a CT contrast agent, served as a model drug; optimization of CT acquisition parameters yielded a sensitivity of 0.21 mg/mL (or 95 microg iodine/mL) for this agent. In vitro validation of the method was carried out by tracking release of iohexol in gelatin gel phantoms. In vivo release in rabbit livers was characterized through quantitative analysis of CT images and compared with UV-Vis analysis of the explanted devices at three implantation times. After correction for respiratory motion, CT analysis correlates well with the extracted iohexol data at all time points. The percent error between the actual and experimental image data was below 10%. This study demonstrates the potential of using computed tomography to noninvasively quantify the rate of agent release from controlled delivery devices in vivo.
منابع مشابه
Noninvasive monitoring of local drug release in a rabbit radiofrequency (RF) ablation model using X-ray computed tomography.
In this study, X-ray computed tomography (CT) was utilized as a noninvasive method to directly examine local drug release kinetics in livers before and following radiofrequency thermal ablation. Iohexol, a CT contrast agent, was used as a drug-mimicking molecule. Release of iohexol in healthy and ablated rabbit livers over 48 h was quantified and correlated with the release profiles from phosph...
متن کاملDesign of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies
Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملMultimodality tumor imaging targeting integrin αvβ3
The cell adhesion molecule integrin αvβ3 is an important player in the process of tumor angiogenesis and metastasis. Antibodies, peptides, peptidomimetics, and small molecule antagonists against integrin αvβ3 have been shown to induce endothelial apoptosis, to inhibit tumor angiogenesis, and to increase endothelial permeability. The ability to quantitatively image integrin αvβ3 expression in vi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of pharmaceutical sciences
دوره 92 2 شماره
صفحات -
تاریخ انتشار 2003