Effect of pre-heating on depth of cure and surface hardness of light-polymerized resin composites.

نویسندگان

  • Carlos A Muñoz
  • Peter R Bond
  • Jenny Sy-Muñoz
  • Daniel Tan
  • John Peterson
چکیده

PURPOSE To evaluate the depth of cure and surface hardness of two resin composites when subjected to three preheating temperatures, three polymerization times and two types of curing lights. METHODS Two resin composites were used in this study (Esthet-X and TPH), three polymerization times (10, 20, 40 seconds), three preheating temperatures (70, 100, 140 degrees F/21.1, 37.7 and 60 degrees C), and two curing lights (halogen and LED). For depth of cure measurements, 180 specimens (4 mm in diameter and 2 mm in depth) were made for 36 combinations of variables. Four Knoop hardness measurements were obtained from both the top and bottom surfaces. For the surface hardness, another 180 (4 x 6 mm) cylindrical specimens were fabricated. Each specimen was sectioned in half and hardness measurements were made at 0.5 mm intervals. Statistical analyses were performed using the multifactor ANOVA at a level of significance of alpha = 0.05. RESULTS For depth of cure, there was a statistical difference among all the main effects (time, temperature and curing light) for both composites (P > 0.001) when the % difference from the top was analyzed. Results indicate that there was an increase in hardness as the temperature of the composite was increased from 70 to 140 degrees F for both composites for either the top or the bottom. The percent difference in hardness was greater when the LED curing light was used compared to the halogen curing light. Overall there was a greater change in hardness when the resin composite was polymerized at 140 degrees F. Although the ISO standard was not met in many cases, there was a significant increase in hardness on both the top and bottom as temperature and curing time increased (P < 0.001). Results for the surface hardness showed that there was a significant statistical difference (P < 0.001) in hardness when the surface hardness at 0.5 and 3.5 mm were analyzed separately. There was a general increase in surface hardness for both the hybrid and microhybrid as time and temperature increased. For both hybrid and microhybrid groups, as the temperature increased, there was an increase in hardness and it was statistically different (P < 0.001). When the percent difference between 70 and 100 degrees F or 70 and 140 degrees F was evaluated, the greatest increase occurred between the 70 and 140 degrees F and minimal increase between 100 and 140 degrees F. Overall, the LED curing light provided a greater surface hardness for the hybrid at both depths than the halogen curing light. For the microhybrid, the halogen curing light provided the greatest surface hardness when the resin was polymerized for 40 seconds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of Exposure Times and Light Curing Sources on Surface Micro-Hardness of a Resin Modified Glass Ionomer

Introduction: The aim of this study was to evaluate the influenceof different light curing systems and curing times on the micro-hardness of aresin modified glass ionomer. Methods: Forty two samples of ResinModified Glass Ionomer (RMGI) were prepared using stainless steel cylindrical mold(8 × 2 mm) and randomly divided into six groups of seven. Three groups werecured with a Quartz Tungsten Halo...

متن کامل

Hardness of composite resin polymerized with different light-curing units

Introduction: The degree of polymerization depends on the type of light-curing unit. The aim of this study was to compare the hardness of composite resin cured by LED and Halogen light curing units. Methods: In this experimental study, 20 cylindrical samples of Tetric Ceram composite were prepared. Half of them were cured with Ultralume 2 LED and the other half with Astralis 7 Halogen light ...

متن کامل

The effect of different insertion techniques on the depth of cure and vickers surface micro-hardness of two bulk-fill resin composite materials

BACKGROUND The aim of this study was to evaluate the Vickers surface micro-hardness and the depth of cure of two bulk-fill resin composites and one incremental-fill resin composite. MATERIAL AND METHODS Two Bulk-fill dental resin composites (X-tra Fil, Voco; Sonic-FillTM 2, Kerr Corporation) and an incremental-fill dental resin composite (Filtek™ Z250 XT, 3M ESPE) were used. Sixty cylindrical...

متن کامل

Effect of pre-heating on the viscosity and microhardness of a resin composite.

The effect of pre-heating resin composite on pre-cured viscosity and post-cured surface hardness was evaluated. Groups of uncured specimens were heated to 60 degrees C and compared with control groups (24 degrees C) with respect to viscosity and surface hardness. Mean (SD) viscosities of the pre-heated specimens (n = 15) were in the range of 285 (13)-377 (11) (Pa) compared with 642 (35)-800 (23...

متن کامل

The Effect of Aging on Nano-Hardness and Modulus of Elasticity of Four Types of Composites: An in-vitro Study

Introduction: Resin composites are an important part of restorative treatment in modern dentistry. There are many trademarks available in Iran market and physico-chemical properties of many of these resin composites are not evaluated yet. This study was carried out to evaluate the physico-chemical properties of four available resin composites and also to assess the effect of aging on their prop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of dentistry

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2008