BACKGROUND Treatment decisions for apnoea of prematurity (AOP) are usually based on nursing staff's documentation of pulse oximeter and heart rate alarms. OBJECTIVE In an observational study, to compare the accuracy of oxygen saturation (SpO2) and heart rate alarm documentation, and the resulting interventions by nursing staff, with objectively registered events using polysomnographic and video recording. METHODS Data on 21 preterm neonates (12 male) with a diagnosis of AOP were analysed. Nursing staff's desaturation (<80% SpO2) and bradycardia (<80/min) alarm documentation was compared with events registered objectively using simultaneous polysomnography. Interventions by nursing staff were evaluated using 24 h video recordings and compared with their chart documentation. Nursing staff had been unaware that the polygraphic and video recordings would be used subsequently for this purpose. RESULTS Median (minimum-maximum) postnatal age was 15.5 (3-65) days. 968 SpO2 desaturation events and 415 bradycardias were documented by polysomnography. Nursing staff registered 23% of these desaturation events, and 60% of bradycardias (n=223, and n=133, respectively). Intraclass correlation coefficient (95% CI) between objectively measured desaturation events and those documented by nursing staff was 0.14 (-0.31 to 0.53); and for bradycardias 0.51 (0.11 to 0.78). 225 nursing staff interventions were registered on video, of which 87 (39%) were documented. CONCLUSIONS The alarm documentation by neonatal intensive care unit staff does not appear to be sufficiently accurate to permit further understanding and treatment of AOP. It is unclear if the alarms missed here would have led to clinical consequences had they been documented.
منابع مشابه
Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit
Background and Objectives: Placement of skin heat probe for continuous monitoring of infant body temperature is one of the main components of neonatal care. Therefore, managing the body temperature of newborns under radiation warmers requires a lot of attention from nurses to prevent unwanted complications. The aim of this study was to determine the appropriate connection point of skin probe fo...
متن کاملThe Correlation between Attachment Behaviors and Fear Of COVID-19 in Mothers with Neonates Admitted to the Neonatal Intensive Care Unit in Hospitals Under the Supervision of Iran University of Medical Sciences in the Covid-19 Pandemic 2021
Background and Aim: Infant hospitalization in the Neonatal Intensive Care Unit (NICU) causes loss or delay in maternal and infant attachment. On the other hand, quarantine and the limits of social distancing during the Covid 19 virus epidemic have psychological consequences, including an increased fear of Covid 19 infection. The aim of this study was to determine the relationship between attach...
متن کاملThe Prevalence of Portal Vein Thrombosis in Children under 3 Years Old with History of Neonatal Umbilical Vein Catheterization in the Neonatal Intensive Care Unit
Background Portal vein thrombosis (PVT) is one of the most common causes of extrahepatic portal hypertension in children, which may follow neonatal umbilical vein catheterization. The incidence rates of catheter-related PVT, in infants and children vary in different studies. This study aimed to determine PVT incidence in the children under 3 years old with a history of neonatal umbilical vein c...
متن کاملInvestigation of environmental stimuli in the neonatal intensive care unit of Ghaem Hospital in Mashhad
Introduction[N1] :One of these annoying stimuli and a major source of stress in the NICU is sound. In neonatal intensive care units, sounds with different intensities and frequencies are produced from different sources such as fan devices, intermittent alarms, ventilators, telephones, door opening and closing, and staff conversations; Studies have reported that the average noise level in the NI...
متن کاملDetermination of Noise Level and Its Sources in the Neonatal Intensive Care Unit and Neonatal Ward
Background: In Neonatal intensive care units (NICU) different sound intensities and frequencies are produced from different sources, which may exert undesirable physiological effects on the infants. The aim of this study was to determine the noise level and its sources in the NICU and neonatal ward of Al-Zahra Hospital of Rasht, Iran. Methods: In this descriptive cross-sectional study, the inte...
متن کاملEducation Based on Interpersonal Psychotherapy on Postpartum Depression in Mothers of Infants Admitted to Neonatal Intensive Care Unit.
Background:The birth of a premature neonate causes increasing possibility of postpartum depression in mothers. The most important parental needs of infant admitted to the neonatal intensive care unit are communicational and informational needs, the present study aimed to investigate the effect of Interpersonal psychotherapy on postpartum depression in mothers of infants admitted to neonatal in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood. Fetal and neonatal edition
دوره 98 6 شماره
صفحات -
تاریخ انتشار 2013