Stuck mechanical tricuspid valve prosthesis: the valve that does not move.

نویسندگان

  • Bahaa M Fadel
  • Odd Bech-Hanssen
  • Mohammed Al-Admawi
  • Bader Al-Mahdi
  • Abdelmohsen Al-Hashim
  • Giovanni Di Salvo
  • Waqas Ahmed
چکیده

A 44-year–old woman underwent mitral valve and tricuspid valve (TV) replacement 6 years earlier using an ATS bileaflet tilting disc prostheses (ATS Medical Inc., Minneapolis, MN) for combined valvular stenosis and regurgitation because of rheumatic heart disease. On a routine clinic visit, the patient reported progressive fatigue and pedal edema over the previous few weeks. On physical examination, she was hemodynamically stable with evidence of elevated jugular venous pressure, hepatomegaly, and 3-mm pitting ankle and leg edema. Cardiac auscultation revealed closing and opening mechanical clicks; however, mitral and tricuspid clicks could not be distinguished. A grade 2/6 holodiastolic rumble and a

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

عوامل موثر بر علل جراحی مجدد دریچه های مصنوعی قلب و بقاء زودرس بعد عمل، بیمارستان امام، 80-1370

Prosthetic valve re-operation has greater mortality and morbidity than primary valve replacement. By recognition of factors influencing on causes of redo operation and preoperative survival, one can select appropriate prosthesis at primary valve replacement and when operation performed at appropriate time, surgical risk can be reduced.Methods and Materials: Two hundred patients that underwent p...

متن کامل

Tricuspid Valve Endocarditis in an Intravenous Drug Abuser: A Case Report

Recently, there have been more reports of cardiac valve infections due to the increasing number of intravenous (IV) drug abusers and chronic renal failure patients. Among cardiac valves, tricuspid valve is most commonly affected in the course of endocarditis. Appropriate management of these patients is a challenging and controversial issue in the field of cardiac surgery. Treatment options in s...

متن کامل

Stuck bioprosthetic aortic valve--a new entity? A case report.

We describe herein a case of bioprosthetic valve malfunction, which closely imitates a stuck valve. Although the term "stuck" was used originally for the immovable mechanical valve leaflets, the echocardiographic manifestation of this malfunction is similar to those of a mechanical one. The clinical presentation of the stuck bioprosthesis is, however, far more benign than a stuck mechanical val...

متن کامل

Fabrication and characterization of nanofibrous tricuspid valve scaffold based on polyurethane for heart valve tissue engineering

Objective(s): Tissue engineering represents a new approach to solve the current complications of the heart valve replacements by offering viable valve prosthesis with growth and remodeling capability. In this project, electrospinning and dip coating techniques were used to fabricate heart valve constructs from medical grade polyurethane (PU). Methods: Fir...

متن کامل

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 126 22  شماره 

صفحات  -

تاریخ انتشار 2012