Corneal power measurements using scheimpflug imaging in eyes with prior corneal refractive surgery.

نویسندگان

  • Jack T Holladay
  • Warren E Hill
  • Andreas Steinmueller
چکیده

PURPOSE To evaluate the accuracy of central corneal power measurements by Scheimpflug imaging (Pentacam) for eyes that had corneal refractive surgery. METHODS This study comprised two groups: a pilot group of 100 eyes with prior hyperopic or myopic LASIK that did not have cataract surgery, and a test group of 41 eyes with prior radial keratotomy (RK) and cataract surgery. In the pilot group, Pentacam images and refraction were taken preoperatively and 3 months after LASIK. The historical method was used to compute the theoretical postoperative keratometry (K) -reading and then compared to the measured equivalent K-reading (EKR) from the Pentacam. The EKR is the same value measured by standard keratometry or topography on the front surface, adjusted for the effect of the back surface power difference from normal. In the test group of RK eyes, the postoperative refraction and EKR were measured 3 months after cataract surgery. The Holladay IOL Consultant Program was used to back-calculate the theoretical K-reading. The EKR measurements were then compared to the back-calculated corneal power. RESULTS The optimal zone sample size was determined to be 4.5 mm for the pilot group. The mean prediction error for this group was -0.06+/-0.56 diopters (D) (range: -1.63 to +/-1.34 D). Using the 4.5-mm zone determined in the pilot group, the EKR value for the test group of 41 RK eyes had a mean prediction error of -0.04+/-0.94 D (range: -1.84 to +/-2.27 D). CONCLUSIONS When historical refractive data are not available, Scheimpflug imaging with the Pentacam provides an alternative method of measuring the central corneal power in eyes that previously received corneal refractive surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery.

PURPOSE To determine the accuracy of Pentacam Scheimpflug system Holladay equivalent keratometry (K) readings (EKRs) in calculating intraocular lens (IOL) power after corneal refractive surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and radial keratotomy (RK). SETTING Jules Stein Eye Institute, David Geffen School of Medicine at University of Calif...

متن کامل

Posterior corneal astigmatism.

In the optical system of the human eye, total refractive power consists mainly of corneal and lenticular components. Approximately two-thirds of the eye's converging power is at the air–cornea (tear film) interface; one-third is in the lens. Total corneal power is determined by corneal anterior and posterior curvature, corneal thickness, and the corneal refractive indices. Traditionally, anteri...

متن کامل

Optical coherence tomography accurately measures corneal power change from laser refractive surgery.

PURPOSE To determine the ability of motion-corrected optical coherence tomography (OCT) to measure the corneal refractive power change due to LASIK. DESIGN Evaluation of a diagnostic test or technology in a cohort. SUBJECTS A total of 70 eyes from 37 subjects undergoing LASIK were measured preoperatively. A total of 39 eyes from 22 subjects were measured postoperatively and completed the st...

متن کامل

Repeatability of aberrometric measurements in normal and keratoconus eyes using a new Scheimpflug-Placido topographer.

PURPOSE To evaluate the repeatability of the anterior and posterior corneal wavefront aberrations using the Sirius Scheimpflug-Placido topographer in normal eyes and keratoconus eyes. SETTING Bozok University Faculty of Medicine, Yozgat, Turkey. DESIGN Evaluation of diagnostic test. METHODS In eyes of healthy subjects and eyes of keratoconus patients, 3 repeated measurements were obtained...

متن کامل

ذخیره در منابع من