Comparison of dynamic contrast-enhanced 3T MR and 64-row multidetector CT angiography for the localization of spinal dural arteriovenous fistulas.
نویسندگان
چکیده
BACKGROUND AND PURPOSE For the localization of spinal dural arteriovenous fistulas, it is not determined whether dynamic contrast-enhanced MRA is more reliable than multidetector CTA. The aim of this study was to compare the agreement between intra-arterial DSA, dynamic contrast-enhanced MRA at 3T, and 64-row multidetector CTA for the localization of spinal dural arteriovenous fistulas. MATERIALS AND METHODS We enrolled 12 consecutive patients (11 men, 1 woman; age range, 46-83 years; mean, 65 years) who underwent preoperative dynamic contrast-enhanced MRA at 3T and 64-row multidetector CTA. The spinal dural arteriovenous fistula location was confirmed by intra-arterial DSA as the reference standard. Two reviewers independently evaluated the level of the artery feeding the spinal dural arteriovenous fistula on the basis of continuity between the feeder and abnormal spinal vessels on 3T dynamic contrast-enhanced MRA and 64-row multidetector CTA images. Interobserver and intermodality agreement was determined by calculation of the κ coefficient. RESULTS On DSA, the vessel feeding the spinal dural arteriovenous fistula was the intercostal artery (7 cases), the lumbar artery (3 cases), and the internal iliac artery or the ascending pharyngeal artery (1 case each). For the fistula level, interobserver agreement was excellent for 3T dynamic contrast-enhanced MRA (κ = 0.97; 95% CI, 0.92-1.00) and very good for 64-row multidetector CTA (κ = 0.84; 95% CI, 0.72-0.96). Intermodality agreement with DSA was good for 3T dynamic contrast-enhanced MRA (κ = 0.78; 95% CI, 0.49-1.00) and moderate for 64-row multidetector CTA (κ = 0.41; 95% CI, 0.020-0.84). CONCLUSIONS For the localization of spinal dural arteriovenous fistulas, 3T dynamic contrast-enhanced MRA may be more reliable than 64-row multidetector CTA.
منابع مشابه
Preangiographic evaluation of spinal dural arteriovenous fistulas with elliptic centric contrast-enhanced MR Angiography and effect on radiation dose and volume of iodinated contrast material.
BACKGROUND AND PURPOSE The detection and localization of spinal dural arteriovenous fistulas (AVFs) remain diagnostic challenges. This study tested the hypothesis that elliptic centric contrast-enhanced MR angiography (MRA) can be used to detect spinal dural AVFs, predict the level of fistulas, and reduce the radiation dose and volume of iodinated contrast material associated with conventional ...
متن کاملSpinal cord vascular disease: characterization with fast three-dimensional contrast-enhanced MR angiography.
BACKGROUND AND PURPOSE Noninvasive characterization of spinal vascular lesions is essential for guiding clinical management, and several MR angiographic techniques have been applied in the past with variable results. The purpose of our study was to assess the potential of a dynamic 3D contrast-enhanced MR angiographic sequence to characterize spinal vascular lesions and to identify their arteri...
متن کاملTime-resolved contrast-enhanced MR angiography of spinal vascular malformations.
BACKGROUND AND PURPOSE The diagnosis of spinal vascular malformations may be challenging on conventional MR imaging because neither the location of the signal abnormality in the spinal cord nor the level of the abnormal flow voids correlates with the level of the fistula. We conducted a retrospective evaluation of the utility of using a time-resolved imaging of contrast kinetics sequence in the...
متن کاملDynamic 3D MR angiography of intra- and extracranial vascular malformations at 3T: a technical note.
Time-resolved, contrast-enhanced 3D MR angiography combined with parallel imaging at 3T was applied to an intracranial arteriovenous malformation, a dural arteriovenous fistula, and an extracranial facial arteriovenous malformation. The temporal resolution was one image every 1.5 seconds. Arterial feeders were depicted in all three cases. Early venous drainage was observed in the intracerebral ...
متن کاملEvaluation of dural arteriovenous fistulas with 4D contrast-enhanced MR angiography at 3T.
BACKGROUND AND PURPOSE Four-dimensional contrast-enhanced MR angiography (4D-CE-MRA) at 3T may replace digital subtraction angiography (DSA) for certain diagnostic purposes in patients with intracranial dural arteriovenous fistula (DAVF). The aim of this study was to test the hypothesis that 4D-CE-MRA at 3T enables the same characterization of intracranial DAVFs as DSA. MATERIALS AND METHODS ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 35 2 شماره
صفحات -
تاریخ انتشار 2014