Interference by new-generation mobile phones on critical care medical equipment

نویسندگان

  • Erik Jan van Lieshout
  • Sabine N van der Veer
  • Reinout Hensbroek
  • Johanna C Korevaar
  • Margreeth B Vroom
  • Marcus J Schultz
چکیده

INTRODUCTION The aim of the study was to assess and classify incidents of electromagnetic interference (EMI) by second-generation and third-generation mobile phones on critical care medical equipment. METHODS EMI was assessed with two General Packet Radio Service (GPRS) signals (900 MHz, 2 W, two different time-slot occupations) and one Universal Mobile Telecommunications System (UMTS) signal (1,947.2 MHz, 0.2 W), corresponding to maximal transmit performance of mobile phones in daily practice, generated under controlled conditions in the proximity of 61 medical devices. Incidents of EMI were classified in accordance with an adjusted critical care event scale. RESULTS A total of 61 medical devices in 17 categories (27 different manufacturers) were tested and demonstrated 48 incidents in 26 devices (43%); 16 (33%) were classified as hazardous, 20 (42%) as significant and 12 (25%) as light. The GPRS-1 signal induced the most EMI incidents (41%), the GRPS-2 signal induced fewer (25%) and the UMTS signal induced the least (13%; P < 0.001). The median distance between antenna and medical device for EMI incidents was 3 cm (range 0.1 to 500 cm). One hazardous incident occurred beyond 100 cm (in a ventilator with GRPS-1 signal at 300 cm). CONCLUSION Critical care equipment is vulnerable to EMI by new-generation wireless telecommunication technologies with median distances of about 3 cm. The policy to keep mobile phones '1 meter' from the critical care bedside in combination with easily accessed areas of unrestricted use still seems warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Interference of the Microwave Radiation Emitted from GSM Mobile Phones on the Performance of Cell Counters

Abstract Background and Objectives: Incidents related to electromagnetic interference with medical devices have been reported over the past decades. It has also been indicated that the microwave radiation emitted from mobile phones interferes with the operation of medical devices therefore, this study aimed at testing the interference by GSM mobile phones with cell counters. Material and Method...

متن کامل

Effects of mobile phone use on specific intensive care unit devices

BACKGROUND AND AIMS To observe the effects of mobile phone use in the vicinity of medical devices used in a critical care setting. SUBJECTS AND METHODS Electromagnetic interference (EMI) was tested by using two types of mobile phones - GSM and CDMA. Mobile phones were placed at a distance of one foot from three medical devices - syringe pump, mechanical ventilator, and the bedside monitor - i...

متن کامل

Modern wireless telecommunication technologies and their electromagnetic compatibility with life-supporting equipment.

Hospitals rely on pagers and ordinary telephones to reach staff members in emergency situations. New telecommunication technologies such as General Packet Radio Service (GPRS), the third generation mobile phone system Universal Mobile Telecommunications System (UMTS), and Wireless Local Area Network (WLAN) might be able to replace hospital pagers if they are electromagnetically compatible with ...

متن کامل

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...

متن کامل

Comments on "Study of Bacterial Contamination of Mobile Phones and Stethoscopes in Neonatal Intensive Care Unit"

This letter is regarding the article by Daoudi et al. entitled "Study of bacterial contamination of mobile phones and stethoscopes in Neonatal Intensive Care Unit" published in International Journal of Pediatrics DOI: 10.22038/IJP.2017.25504.2170 (1). The authors have evaluated the microbial contamination of mobile phones and stethoscopes used by medical and paramedical staff. They reported tha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2007