[Sensitivity of size I stimulus in achromatic automated perimetry for detection of glaucomatous visual field defects: a comparative analysis with short wavelength automated perimetry and standard automated perimetry (SITA)].

نویسندگان

  • Tessa de Cerqueira Lemos Mattos
  • Niro Kasahara
  • Maurício Della Paolera
  • Ralph Cohen
  • Carmo Mandia Junior
  • Geraldo Vicente de Almeida
چکیده

PURPOSE To compare sensitivity and specificity of achromatic perimetry with size I stimulus (WW-I) with standard automated perimetry (SITA strategy) and blue on yellow perimetry (SWAP) for early diagnosis of glaucoma. METHODS Seventy-three eyes of 73 suspects, glaucomatous and normal subjects underwent automated perimetry with SITA 24-2, WW-I and SWAP. After application of specific criteria of abnormality, sensitivity, specificity, and the area under ROC (Receiver Operating Characteristic) curve were calculated for each of the examinations. The areas under the ROC curve were compared pair-wisely with the univariable Z test and significance set at 5%. RESULTS WW-I displayed the greatest sensitivity (100%) and the lowest specificity (75.7%). SWAP revealed less sensitivity (69.4%); specificity, however, was higher (89.2%). Pairwise comparison of ROC curves showed no difference. CONCLUSION WW-I revealed good sensitivity for the detection of early glaucomatous visual field defects. This technique adds to the available armamentarium for early functional diagnosis of glaucomatous optic neuropathy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.

PURPOSE To compare the performance of standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, and short-wavelength automated perimetry (SWAP) in detecting glaucoma. METHODS One hundred thirty-two eyes of 95 glaucoma patients and 37 normal subjects had retinal nerve fiber layer (RNFL) imaging and visual field testing by SAP, Matrix FDT perimetry, and Swedish interact...

متن کامل

Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.

PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...

متن کامل

Topography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields.

BACKGROUND Traquair described the topography of visual field sensitivity as a "hill" or "island" of vision. Achromatic automated perimetry (AAP) demonstrates this shape of the visual field in photopic conditions. Techniques claimed to target the magnocellular pathway (frequency doubling perimetry, FDP) and those using a stimulus targeting the koniocellular pathway (short wavelength (or blue on ...

متن کامل

A new rapid threshold algorithm for short-wavelength automated perimetry.

PURPOSE To develop and test a short and reliable visual field threshold program for the early detection of glaucomatous visual field loss, by adapting the Swedish interactive test algorithm (SITA) to short-wavelength-automated-perimetry (SWAP). METHODS Computer simulations were performed to test the accuracy of several versions of SITA SWAP, and to optimize speed versus reliability. The selec...

متن کامل

Relationship between retinal sensitivity and disease activity in patients with psoriasis vulgaris

OBJECTIVES Psoriasis is a hyperproliferative chronic inflammatory skin disease of unknown etiology and ocular structures and visual pathways can also be affected during the course of this disease. Subclinical optic neuritis has previously been observed in psoriatic patients in visual evoked potential studies. This trial was designed to evaluate retinal sensitivity in patients with psoriasis vul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 71 2  شماره 

صفحات  -

تاریخ انتشار 2008