Use of an Insulin Bolus Advisor Improves Glycemic Control in Multiple Daily Insulin Injection (MDI) Therapy Patients With Suboptimal Glycemic Control

نویسندگان

  • Ralph Ziegler
  • David A. Cavan
  • Iain Cranston
  • Katharine Barnard
  • Jacqueline Ryder
  • Claudia Vogel
  • Christopher G. Parkin
  • Walter Koehler
  • Iris Vesper
  • Bettina Petersen
  • Matthias A. Schweitzer
  • Robin S. Wagner
چکیده

OBJECTIVE Use of automated bolus advisors is associated with improved glycemic control in patients treated with insulin pump therapy. We conducted a study to assess the impact of using an insulin bolus advisor embedded in a blood glucose (BG) meter on glycemic control and treatment satisfaction in patients treated with multiple daily insulin injection (MDI) therapy. The study goal was to achieve >0.5% A1C reduction in most patients. RESEARCH DESIGN AND METHODS This was a 26-week, prospective, randomized, controlled, multinational study that enrolled 218 MDI-treated patients with poorly controlled diabetes (202 with type 1 diabetes, 16 with type 2 diabetes) who were 18 years of age or older. Participants had mean baseline A1C of 8.9% (SD, 1.2 [74 mmol/mol]), mean age of 42.4 years (SD, 14.0), mean BMI of 26.5 kg/m(2) (SD, 4.2), and mean diabetes duration of 17.7 years (SD, 11.1). Control group (CNL) patients used a standard BG meter and manual bolus calculation; intervention group (EXP) patients used the Accu-Chek Aviva Expert meter with an integrated bolus advisor to calculate insulin dosages. Glucose data were downloaded and used for therapy parameter adjustments in both groups. RESULTS A total of 193 patients (CNL, n = 93; EXP, n = 100) completed the study. Significantly more EXP than CNL patients achieved >0.5% A1C reduction (56.0% vs. 34.4%; P < 0.01). Improvement in treatment satisfaction (Diabetes Treatment Satisfaction Questionnaire scale) was significantly greater in EXP patients (11.4 [SD, 6.0] vs. 9.0 [SD, 6.3]; P < 0.01). Percentage of BG values <50 mg/dL was <2% in both groups during the study. CONCLUSIONS Use of an automated bolus advisor resulted in improved glycemic control and treatment satisfaction without increasing severe hypoglycemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of automated bolus advisors may improve adherence to multiple daily insulin injection therapy.

Corresponding Author: Christopher G. Parkin, CGParkin Communications, 219 Red Rock Road, Boulder City, NV; email address [email protected] Automated bolus advisors provide the capability to automatically calculate bolus insulin dosages to cover carbohydrate intake and address out-of-range blood glucose levels, and they have been shown to be safe and effective in reducing postprandial glucose e...

متن کامل

Use of an automated bolus calculator reduces fear of hypoglycemia and improves confidence in dosage accuracy in patients with type 1 diabetes mellitus treated with multiple daily insulin injections.

BACKGROUND Many patients do not intensify their insulin regimens. It is believed that lack of adherence may be largely due to fear of hypoglycemia. We hypothesized that utilization of an automated bolus calculator (bolus advisor) might reduce fear of hypoglycemia and encourage patients to achieve improved glycemic control. METHOD We surveyed 1,412 type 1 diabetes mellitus (T1DM) patients trea...

متن کامل

Changes in Glycemic Control and Quality of Life in Pediatric Type 1 Diabetics with Continuous Subcutaneous Insulin Infusion of Insulin Aspart Following Multiple Daily Injection Therapy

The efficacy of continuous subcutaneous insulin infusion (CSII) of the rapid-acting insulin analogue, insulin aspart, was evaluated in 26 patients with childhood-onset type 1 diabetes aged between 6 and 18 yr who had been on basal-bolus therapy (multiple daily injection (MDI) of regular human insulin or rapid-acting insulin and intermediate/long-acting insulin). The glycemic control in the pati...

متن کامل

A feasibility study of a 3-day basal-bolus insulin delivery device in individuals with type 2 diabetes.

OBJECTIVE This study tested the feasibility of transition from multiple daily injections (MDI) to a 3-day, basal-bolus insulin delivery device (PaQ) for type 2 diabetes (T2D). RESEARCH DESIGN AND METHODS Twenty MDI-treated individuals with T2D with HbA(1c) ≤9% (75 mmol/mol) were enrolled in a single-center, single-arm pilot study, lasting three 2-week periods: baseline (MDI), transition to Pa...

متن کامل

Combined insulin pump therapy with real-time continuous glucose monitoring significantly improves glycemic control compared to multiple daily injection therapy in pump naïve patients with type 1 diabetes; single center pilot study experience.

OBJECTIVES This study assessed the safety and clinical effectiveness of the training protocol for initiating insulin pump therapy with real-time continuous glucose monitoring (MiniMed Paradigm REAL-Time System) in a stepwise approach on pump naive subjects with type 1 diabetes compared to a control group who remained on multiple daily injection (MDI) therapy. METHODS This was a 15-week treat-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2013