How many times per day should peak expiratory flow rates be assessed when investigating occupational asthma?
نویسندگان
چکیده
BACKGROUND Serial peak expiratory flow rate (PEF) recording has been advocated as a sensitive and specific means of confirming work related asthma. The optimum number of recordings per day to achieve the best between-reader and within-reader reproducibility and sensitivity/specificity ratio compared with the final diagnosis determined by specific inhalation challenges is unknown. METHODS PEF recording was carried out every two hours in 74 subjects referred for possible occupational asthma. Specific inhalation challenges performed in a hospital laboratory or at the workplace (positive in 33 subjects and negative in 41) were considered the gold standard. The duration of monitoring at work and away from work was at least two weeks each. Graphs of PEF recordings were generated in four different ways: every two hours, four times/day, three times/day, and every morning and evening. The graphs were assessed by three readers in three different centres in a blind manner. Furthermore, one third of each type of graph was read blind by the same reader one week after the initial interpretation. RESULTS Agreement between the three readers was a little more frequent (82%) in the case of the every two hour readings than for the other types of readings (70% v 77%). Agreement between at least two of the three readers occurred in 73% of positive challenges (sensitivity) and in 78% of negative challenges (specificity) for every two hour readings. The figures varied from 61% to 70% for positive challenges and from 78% to 88% for negative challenges for the other types of readings. Within-subject reproducibility from one reading to the next (one week apart) was excellent (83% to 100%). CONCLUSIONS Recording PEF every two hours results in a slightly more satisfactory agreement between readers and in concordance in terms of sensitivity/specificity than less frequent PEF readings, although the four times a day assessment is almost as satisfactory.
منابع مشابه
Peak Expiratory Flow Rate in Healthy Children from Tehran
Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines. Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...
متن کاملEffect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma.
Serial peak expiratory flow records are recommended in the first-line investigation of suspected occupational asthma. The effects of sequentially reducing the numbers of working weeks, consecutive days at work and readings taken per day on diagnostic sensitivity and specificity were investigated, using good quality peak expiratory flow records from 81 workers with independently confirmed occupa...
متن کاملPEF analysis requiring shorter records for occupational asthma diagnosis.
BACKGROUND The Oasys programme plots serial peak expiratory flow (PEF) measurements and produces scores of the likelihood that the recordings demonstrate occupational asthma. We have previously shown that the area between the mean workday and rest day PEF curves [the area between the curves (ABC) score] has a sensitivity of 69% and specificity of 100% when plotted from waking time using a cut-o...
متن کاملOccupational asthma: validity of monitoring of peak expiratory flow rates and non-allergic bronchial responsiveness as compared to specific inhalation challenge.
The sensitivity and specificity of monitoring peak expiratory flow rates (PEFR) and bronchial responsiveness to the provocative concentration of histamine or methacholine (PC20) has been determined as compared to specific inhalation challenges in the diagnosis of occupational asthma. A prospective study of 61 subjects referred for occupational asthma to various agents was performed. PEFR was as...
متن کاملPeak expiratory flow analysis in workers exposed to detergent enzymes.
AIMS To study serial peak expiratory flow (PEF) responses in a group of symptomatic detergent enzyme-exposed workers. METHODS Workers were recruited from a biological detergent formulating and packaging company. Those with occupational asthma symptoms and/or specific IgE to a detergent enzyme were asked to complete 2 hourly PEF measurements for 4 weeks. Outputs from the Oasys program (Oasys s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 48 12 شماره
صفحات -
تاریخ انتشار 1993