Evaluation of neurotoxicity of artificial dura mater and dura mater containing a high concentration of dibutyltin in rats after intracranial implantation
نویسندگان
چکیده
1 Department of Preventive Medicine, Kitasato University School of Medicine 2 Graduate School of Medical Sciences, Kitasato University 3 Department of Hygiene and Preventive Medicine, Fukushima Medical University School of Medicine 4 Hirosaki University Graduate School of Health Sciences 5 Department of Public Health, Kitasato University School of Allied Health Sciences 6 Department of Physiology, Kitasato University School of Allied Health Sciences 7 Kawasumi Laboratories, Inc. 8 National Center for Geriatrics and Gerontology 9 Medical Center for Translational Research, Osaka University Hospital
منابع مشابه
Higher toxicity of dibutyltin and poly-L-lactide with a large amount of tin but lower toxicity of poly-L-lactide of synthetic artificial dura mater exhibited on murine astrocyte cell line.
Neurotoxicities of dibutyltin (DBT), tin(II) octylate (OT), poly-L-lactides (PLLA, molecular weight [MW]=5000, PLLA 5000), PLLA without tin (MW=3000, PLLA 3000), PLLA with a large amount (590 ppm) of tin (S3), poly(glycolic acid-co-epsilon-caprolactone) oligomer (MW=6200, PGC oligomer), and poly(L-lactic acid-co-glycolic acid-co-epsilon-caprolactone) oligomer (MW=6400, PLGC oligomer) related to...
متن کاملکاربرد پرده آمنیوتیک جفت انسان برای ترمیم سخت شامه در سگ
This study was conducted to show the comparison of efficacy and survival of amniotic membrane grafts and homologous dura grafts.Methods and Materials: In this study, ten dogs (age 6-9 months & weight 15 lo 20 kg) have been chosen. The study was a single blind clinical trial. The dogs have been assigned into two groups by random allocation method. The amniotic membrane (A.M) was taken from a pla...
متن کاملAn alginate hydrogel dura mater replacement for use with intracortical electrodes.
The collagenous dura mater requires a secure closure following implantation of neural prosthetic devices to avoid complications due to cerebrospinal fluid leakage and infections. Alginate was previously suggested for use as a dural sealant. The liquid application and controllable gelling conditions enable alginate to conform to the unique geometries of a neural prosthetic device and the surroun...
متن کاملSolitary Intracranial Plasmacytoma In A child Report of a 7-year-old gid
A ease is reported of large intracranial plasmacytoma arising from the dura mater and involving the dura of the left cerebral convexity. tentorium eerebelli and the dura of the posterior
متن کاملClinical experience with expanded polytetrafluoroethylene sheet used as an artificial dura mater.
Dural repair using chemically treated cadaveric dura mater often results in atrophic and fragile change of the substitute as well as adhesion between the dura mater and brain surface at reoperation. Creutz-feldt-Jakob disease has occurred after repair using cadaveric dura mater. Expanded polytetrafluoroethylene (EPTFE) surgical sheet was used for dural repair in 34 patients. Suturing of EPTFE w...
متن کامل