Myocardial ASL-CMR perfusion imaging with improved sensitivity using GRAPPA
نویسندگان
چکیده
Background Myocardial arterial spin labeling (ASL) is a non-contrast CMR technique for measuring myocardial blood flow (MBF), but has relatively low signal-to-physiological noise (PN). Therefore perfusion measurements are made over several averaged pixels within left ventricular (LV) segments and not individual pixels. Shorter image acquisition times using SENSE parallel imaging has been shown to significantly reduce PN and improve sensitivity to MBF. However, SENSE is unable to reconstruct images at a field of view (FOV) smaller than the object being imaged and requires a large FOV, which leads to fewer number of pixels for averaging in the LV. In this study, we demonstrate that GRAPPA parallel imaging (rate 1.6), which has no such FOV restrictions, reduces PN even further than SENSE (rate 2), despite having a longer image acquisition window.
منابع مشابه
Arterial spin labeled MRI detects clinically relevant increases in myocardial blood flow with vasodilatation
OBJECTIVES This study sought to determine whether arterial spin labeled (ASL) cardiac magnetic resonance (CMR) is capable of detecting clinically relevant increases in regional myocardial blood flow (MBF) with vasodilator stress testing in human myocardium. BACKGROUND Measurements of regional myocardial perfusion at rest and during vasodilatation are used to determine perfusion reserve, which...
متن کاملArterial spin labeling CMR perfusion imaging is capable of continuously monitoring myocardial blood flow during stress
Background Myocardial arterial spin labeling (ASL) is a non-invasive non-contrast CMR perfusion imaging technique [Zun et al., ‘09] that is compatible with adenosine stress testing [Zun et al., ‘11]. Here, we demonstrate its ability to continuously monitor MBF during stress, which has a variety of potential applications including interventional CMR and the study of endothelial function. We used...
متن کاملk-t-Space accelerated myocardial perfusion.
PURPOSE To investigate the performance of the recently introduced spatiotemporal parallel imaging technique called parallel MRI with extended and averaged generalized autocalibrating partially parallel acquisitions (GRAPPA) kernels (PEAK-GRAPPA) for myocardial perfusion measurements. MATERIALS AND METHODS A study with 11 patients with myocardial infarction was performed to compare nonaccelera...
متن کاملArterial Spin Labeled MRI Detects Increase in Myocardial Blood Flow with Adenosine
INTRODUCTION Myocardial arterial spin labeling (ASL) is an emerging technique for the assessment of myocardial perfusion. ASL does not require any contrast agents, and therefore can be used in patients with renal failure, and can be performed continuously during an intervention. Furthermore, ASL has the potential to provide quantitative measurement of regional myocardial blood flow (MBF) in ml-...
متن کاملMyocardial arterial spin labeling perfusion imaging with improved sensitivity
BACKGROUND Myocardial arterial spin labeling (ASL) is a noninvasive MRI based technique that is capable of measuring myocardial blood flow (MBF) in humans. It suffers from poor sensitivity to MBF due to high physiological noise (PN). This study aims to determine if the sensitivity of myocardial ASL to MBF can be improved by reducing image acquisition time, via parallel imaging. METHODS Myocar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -
تاریخ انتشار 2016