SU-E-I-15: Comparison of State-Of-The-Art Interpolation-Based Metal Artifact Reduction (MAR) Algorithms for Cone-Beam Computed Tomography (CBCT).

نویسندگان

  • D Seghers
  • T Berkus
  • M Oelhafen
  • P Munro
  • J Star-Lack
چکیده

PURPOSE To compare four metal-artifact-reduction (MAR) algorithms in their ability to correct the typical streaking artifacts that appear in cone- beam computed tomography (CBCT) images. METHODS The goal was to compare the strengths and weaknesses of four MAR algorithms, Basic; Wei; Mazin and Meyer, using typical clinical situations where metal is present. Three clinical situations were evaluated: fiducial markers in the abdomen; hip implants and multiple dental fillings. The algorithms take original CBCT projections as input and produce a corrected image. The location of the metal is identified in the CBCT images and a forward projection identifies which pixels in the projections need to be replaced by interpolation of neighboring pixels. The three advanced algorithms extend the Basic technique with more sophisticated interpolation schemes. Wei and Meyer identify the high contrast structures using image segmentation in order to reduce their appearance in the projections before interpolation. Mazin corrects the original projections using a forward projection of the Basic correction. RESULTS All the algorithms reduced the streak artifacts typical of metal structures. Nevertheless, depending upon the clinical task, the algorithms also added shading and streaks which reduced the overall visual impression. Images containing fiducial markers in the abdomen showed obvious improvements; images containing hip implants were improved but also showed distracting shading artifacts; and, images with multiple dental fillings all appeared visually worse than the uncorrected images. In almost all cases, Mazin outperformed the other approaches and introduced the fewest additional streaks and shading artifacts. CONCLUSIONS This work indicates that the Mazin algorithm is best suited for clinical usage of MAR. Furthermore the algorithm is fairly simple and can be computational very efficient making it well suited for clinical use. Nevertheless, the overall improvement is highly dependent on the individual characteristics of the original image. For dental implants no correction is recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

Evaluation of Metal Artifacts in Cone Beam Computed Tomography by Metal Supported Porcelain Crowns Using Different FOV and Localizations: An In Vitro Study

Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods:</...

متن کامل

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

Metal artifact production and reduction in CBCT with different numbers of basis images

Purpose To evaluate the effect of different numbers of basis images and the use of metal artifact reduction (MAR) on the production and reduction of artifacts in cone-beam computed tomography images. Materials and Methods An acrylic resin phantom with a metal alloy sample was scanned, with 450 or 720 basis images and with or without MAR. Standard deviation values for the test areas (around th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part4  شماره 

صفحات  -

تاریخ انتشار 2012