The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability.

نویسندگان

  • Carlo Ercoli
  • Paul D Funkenbusch
  • Han-Joo Lee
  • Mark E Moss
  • Gerald N Graser
چکیده

PURPOSE The authors evaluated, under conditions simulating implant placement, the cutting efficiency, durability, heat production, and wear of implant drills. MATERIALS AND METHODS Osteotomies were performed on bovine ribs using a surgical unit mounted in a testing apparatus. A software program controlled the apparatus and recorded temperatures, depths, and drilling times. Seven brands of drills were tested (Nobel Biocare, 3i/Implant Innovations, Steri-Oss, Paragon, Implamed, Lifecore, and ITI). Spade, twist, tri-flute, and TiN-coated drill designs were evaluated and compared during 100 successive osteotomies. Scanning electron microscopic and energy-dispersive x-ray spectroscopic examinations were performed, and hardness was measured. RESULTS Two 2-mm drills (Nobel Biocare and 3i/Implant Innovations) had mean removal rates significantly greater than the others (P < .05). The 2-mm twist drill design with a low hardness (Implamed) exhibited plastic deformation at the cutting edge, loss of cutting efficiency, and drill fracture. The TiN-coated drills (Steri-Oss and Paragon) showed greater wear and significantly lower removal rates (P < .05) than noncoated drills. Temperature increases with different drills were not significantly different at depths of 5 or 15 mm or between 2-mm or 3-mm drills. With 1 exception (the 2.3-mm Paragon drill at a depth of 15 mm), the temperatures generated by the different types of drills were not significantly different. Clinically harmful temperatures were detected only at a depth of 15 mm during 5 osteotomies and coincided with a marked decrease in the rate of drill advancement with a resulting continuous drilling action. DISCUSSION Temperatures generated at depths of 5 and 15 mm by the different drill types and diameters were not significantly different and, with only 5 exceptions, were clinically safe. Several differences between brands were noted in regard to cutting efficiency and durability, underscoring the importance of material selection and quality on drill performance. CONCLUSIONS Drill design, material, and mechanical properties significantly affect cutting efficiency and durability. Coolant availability and temperature were the predominant factors in determining bone temperatures. Implant drills can be used several times without resulting in bone temperatures that are potentially harmful. Continuous drilling in deep osteotomies can produce local temperatures that might be harmful to the bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DRILL WEAR PREDICTION SYSTEM USING OF MOTOR CURRENT AND FUZZY LOGIC METHOD

In automation flexible manufacturing systems, tool wear detection during the cutting process is one of the most important considerations. This study presents an intelligent system for online tool condition monitoring in drilling process .In this paper, analytical and empirical models have been used to predict the thrust and cutting forces on the lip and chisel edges of a new drill. Also an empi...

متن کامل

Heat generation and drill wear during dental implant site preparation: systematic review.

To identify factors that minimise damage during the drilling of sites for dental implants, we reviewed published papers on the amount of heat that is generated. We systematically searched English language studies published between January 2000 and February 2014 on MEDLINE/PubMed and found 41 articles, of which 27 related to an increase in temperature during preparation of the site. We found onl...

متن کامل

Comparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants.

PURPOSE To determine whether a wire-guided single drill protocol could be utilized without causing an increase in bone temperature beyond those seen with the traditional techniques of sequential drilling with and without a drill guide. MATERIALS AND METHODS A bovine femoral bone model was used with thermocouples and infrared temperature measurements to record thermal increase of the bone and ...

متن کامل

FEM investigation of drilling conditions on heat generation during teeth implantation

Abstract The first step of implanting teeth is to drill a hole in the jaw bone. Excessive temperature produced during drilling is one of the destructive factors for bony tissue. If the temperature generation during surgical drilling exceeds the critical temperature, it could lead to osteonecrosis. This research intends to study drilling parameters such as drilling speed, feed rate, cooling con...

متن کامل

Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills.

OBJECTIVES The purpose was to assess thermal changes and drill wear in bovine bone tissue with the use of twisted stainless steel and zirconia-based drills, during implant site preparation. METHODS A total of 100 implant site preparations were performed on bovine ribs using a surgical unit linked to a testing device, in order to standardize/simulate implant drilling procedures. Bone temperatu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2004