Why would cement porosity reduction be clinically irrelevant, while experimental data show the contrary.
نویسندگان
چکیده
Laboratory bench tests have shown that porosity reduction increases the fatigue life of bone cement specimens. Clinically, however, the effect porosity reduction is subject to debate. We hypothesized that the discrepancy between clinical and experimental findings is related to differences in the stress distribution, which is typically uniform in experimental test specimens, while stress concentrations exist in cement around hip implants. We simulated fatigue failure of cement in a finite element model of an experimental test specimen and of a transverse slice of a total hip arthroplasty with a sharp-cornered stem. Four levels of porosity were introduced. In the fatigue test specimen model, the fatigue life clearly was dependent on the level of porosity, while in the transverse slice model, the level of porosity had virtually no effect on failure of the cement mantle. The results of the simulations confirmed our hypothesis. In simulations of laboratory tests, pores clearly acted as crack initiators, while in the simulation of a real total hip reconstruction, crack formation was governed by local stress singularities. This explains why the beneficial effect of cement porosity reduction on the lifetime of total hip reconstructions may be hard to detect clinically.
منابع مشابه
Vacuum-mixing cement does not decrease overall porosity in cemented femoral stems: an in vitro laboratory investigation.
The role of vacuum mixing on the reduction of porosity and on the clinical performance of cemented total hip replacements remains uncertain. We have used paired femoral constructs prepared with either hand-mixed or vacuum-mixed cement in a cadaver model which simulated intra-operative conditions during cementing of the femoral component. After the cement had cured, the distribution of its poros...
متن کاملPorosity reduction in bone cement at the cement-stem interface.
The fatigue failure of bone cement, leading to loosening of the stem, is likely to be one mode of failure of cemented total hip replacements. There is strong evidence that cracks in the cement are initiated at voids which act as stress risers, particularly at the cement-stem interface. The preferential formation of voids at this site results from shrinkage during polymerisation and the initiati...
متن کاملتاثیر مداخلات ترکیبی برجستگی مرگ بر حرمت خود با توجه به ملاحظات تاخیر زمانی
Abstract Terror management theory attempts to answer two fundamental questions: Why do people have a strong tendency to love themselves and why do they avoid whom are not similar to them? According to this theory the man’s survival tendency is the answer of these two questions. This theory claims that people reduce terror of death by gaining sense of valuableness and also by being attr...
متن کاملInfluence of Pore Structure on Compressive Strength of Cement Mortar
This paper describes an experimental investigation into the pore structure of cement mortar using mercury porosimeter. Ordinary Portland cement, manufactured sand, and natural sand were used. The porosity of the manufactured sand mortar is higher than that of natural sand at the same mix proportion; on the contrary, the probable pore size and threshold radius of manufactured sand mortar are fin...
متن کاملPorosity prediction of calcium phosphate cements based on chemical composition.
The porosity of calcium phosphate cements has an impact on several important parameters, such as strength, resorbability and bioactivity. A model to predict the porosity for biomedical cements would hence be a useful tool. At the moment such a model only exists for Portland cements. The aim of this study was to develop and validate a first porosity prediction model for calcium phosphate cements...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic research : official publication of the Orthopaedic Research Society
دوره 23 4 شماره
صفحات -
تاریخ انتشار 2005