An Iterative Bézier Method for Fitting Beta-sheet Component of a Cryo-EM Density Map

نویسنده

  • Jing He
چکیده

Cryo-electron microscopy (Cryo-EM) is a powerful technique to produce 3-dimensional density maps for large molecular complexes. Although many atomic structures have been solved from cryo-EM density maps, it is challenging to derive atomic structures when the resolution of density maps is not sufficiently high. Geometrical shape representation of secondary structural components in a medium-resolution density map enhances modeling of atomic structures. We compare twomethods in producing surface representation of the β-sheet component of a density map. Given a 3-dimensional volume of β-sheet that is segmented from a density map, the performance of a polynomial fitting was compared with that of an iterative Bézier fitting. The results suggest that the iterative Bézier fitting is more suitable for β-sheets, since it provides more accurate representation of the corners that are naturally twisted in a β-sheet.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tracing beta strands using StrandTwister from cryo-EM density maps at medium resolutions.

Major secondary structure elements such as α helices and β sheets can be computationally detected from cryoelectron microscopy (cryo-EM) density maps with medium resolutions of 5-10 Å. However, a critical piece of information for modeling atomic structures is missing, because there are no tools to detect β strands from cryo-EM maps at medium resolutions. We propose a method, StrandTwister, to d...

متن کامل

Structure of HIV-1 Capsid Assemblies by Cryo-electron Microscopy and Iterative Helical Real-space Reconstruction

Cryo-electron microscopy (cryo-EM), combined with image processing, is an increasingly powerful tool for structure determination of macromolecular protein complexes and assemblies. In fact, single particle electron microscopy and two-dimensional (2D) electron crystallography have become relatively routine methodologies and a large number of structures have been solved using these methods. At th...

متن کامل

FOLD-EM: automated fold recognition in medium- and low-resolution (4-15 Å) electron density maps

MOTIVATION Owing to the size and complexity of large multi-component biological assemblies, the most tractable approach to determining their atomic structure is often to fit high-resolution radiographic or nuclear magnetic resonance structures of isolated components into lower resolution electron density maps of the larger assembly obtained using cryo-electron microscopy (cryo-EM). This hybrid ...

متن کامل

Subnanometer-resolution electron cryomicroscopy-based domain models for the cytoplasmic region of skeletal muscle RyR channel.

The skeletal muscle Ca(2+) release channel (RyR1), a homotetramer, regulates the release of Ca(2+) from the sarcoplasmic reticulum to initiate muscle contraction. In this work, we have delineated the RyR1 monomer boundaries in a subnanometer-resolution electron cryomicroscopy (cryo-EM) density map. In the cytoplasmic region of each RyR1 monomer, 36 alpha-helices and 7 beta-sheets can be resolve...

متن کامل

Tools for the cryo-EM gold rush: going from the cryo-EM map to the atomistic model

As cryo-electron microscopy (cryo-EM) enters mainstream structural biology, the demand for fitting methods is high. Here, we review existing flexible fitting methods for cryo-EM. We discuss their importance, potential concerns and assessment strategies. We aim to give readers concrete descriptions of cryo-EM flexible fitting methods with corresponding examples.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017