Comparison of dose distribution in IMRT and RapidArc technique in prostate radiotherapy.

نویسندگان

  • Wojciech Leszczyński
  • Krzysztof Slosarek
  • Marta Szlag
چکیده

AIM The aim was to provide a dosimetric comparison between IMRT and RapidArc treatment plans with RPI index with simultaneous comparison of the treatment delivery time. BACKGROUND IMRT and RapidArc provide highly conformal dose distribution with good sparing of normal tissues. However, a complex spatial dosimetry of IMRT and RapidArc plans hampers the evaluation and comparison between plans calculated for the two modalities. RPI was used in this paper for treatment plan comparisons. The duration of the therapeutic session in RapidArc is reported to be shorter in comparison to therapeutic time of the other dynamic techniques. For this reasons, total treatment delivery time in both techniques was compared and discussed. MATERIALS AND METHODS 15 patients with prostate carcinoma were randomly selected for the analysis. Two competitive treatment plans using respectively the IMRT and RapidArc techniques were computed for each patient in Eclipse planning system v. 8.6.15. RPIwin(®) application was used for RPI calculations for each treatment plan. Additionally, total treatment time was compared between IMRT and RapidArc plans. Total treatment time was a sum of monitor units (MU) for each treated field. RESULTS The mean values of the RPI indices were insignificantly higher for IMRT plans in comparison to rotational therapy. Comparison of the mean numbers of monitor units confirmed that the use of rotational technique instead of conventional static field IMRT can significantly reduce the treatment time. CONCLUSION Analysis presented in this paper, demonstrated that RapidArc can compete with the IMRT technique in the field of treatment plan dosimetry reducing the time required for dose delivery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

Step-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer

Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...

متن کامل

RapidArc: Initial experience in high grade glioma

Background: Identify the optimal technique of radiotherapy for patients with high grade glioma. Our initial year of experience with RapidArc radiation therapy. Materials and Methods: Planning CT scans of 50 patients with grade IV glioma were reviewed and three plan sets by 3D Conformal Radiotherapy (3DCRT), Intensity Modulated Radiotherapy (IMRT) and Rapid Arc (RA) were generated and the plans ...

متن کامل

Dosimetric and clinical toxicity comparison of critical organ preservation with three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and RapidArc for the treatment of locally advanced cancer of the pancreatic head.

PURPOSE We compared dosimetry and clinical toxicity for 3-dimensional conformal radiotherapy (3D-crt), intensity-modulated radiotherapy (imrt), and RapidArc (Varian Medical Systems, Palo Alto, CA, U.S.A.) in locally advanced pancreatic cancer (lapcc). We hypothesized that the technique with better sparing of organs at risk (oars) and better target dose distributions could lead to decreased clin...

متن کامل

Radiation treatment planning for prostate cancer: A new dosimetric comparison of five and seven fields IMRT plans

Background: To compare the dosimetric coverage of the planning target volume (PTV) and the dose delivered to the main Organs at Risk (OARs) in 5 and 7-field techniques of Intensity Modulated Radiation Therapy (IMRT) in patients with local prostate cancer. Materials and Methods: Twelve patients with local prostate cancer underwent 5 and 7-field IMRT planning. The delivery of IMRT was carried out...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 2012