Ultrahigh speed volumetric ophthalmic OCT imaging at 850nm and 1050nm Citation
نویسندگان
چکیده
The performance and imaging characteristics of ultrahigh speed ophthalmic optical coherence tomography (OCT) are investigated. In vivo imaging results are obtained at 850nm and 1050nm using different configurations of spectral and swept source / Fourier domain OCT. A spectral / Fourier domain instrument using a high speed CMOS linescan camera with SLD light source centered at 850nm achieves speeds of ̃91,000 axial scans per second with ̃3um axial resolution in tissue. A spectral / Fourier domain instrument using an InGaAs linescan camera with SLD light source centered at 1050nm achieves ̃47,000 axial scans per second with ̃7um resolution in tissue. A swept source instrument using a novel wavelength swept laser light source centered at 1050nm achieves 100,000 axial scans per second. Retinal diseases seen in the clinical setting are imaged using the 91kHz 850nm CMOS camera and 47kHz 1050nm InGaAs camera based instruments to investigate the combined effects of varying speed, axial resolution, center wavelength, and instrument sensitivity on image quality. The novel 1050nm swept source / Fourier domain instrument using a recently developed commercially available short cavity laser source images at 100,000 axial scans per second and is demonstrated in the normal retina. The dense 3D volumetric data sets obtained with ultrahigh speed OCT promise to improve reproducibility of quantitative measurements, enabling early diagnosis as well as more sensitive assessment of disease progression and response to therapy.
منابع مشابه
Ultrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second.
We demonstrate ultrahigh speed swept source/Fourier domain ophthalmic OCT imaging using a short cavity swept laser at 100,000 - 400,000 axial scan rates. Several design configurations illustrate tradeoffs in imaging speed, sensitivity, axial resolution, and imaging depth. Variable rate A/D optical clocking is used to acquire linear-in-k OCT fringe data at 100 kHz axial scan rate with 5.3 um axi...
متن کاملUltrahigh speed spectral / Fourier domain ophthalmic OCT imaging
Ultrahigh speed spectral / Fourier domain optical coherence tomography (OCT) using a CMOS line scan camera with image acquisition rates of 70,000 312,500 axial scans per second is investigated. Several design configurations are presented to illustrate design trade-offs between acquisition speed, sensitivity, resolution and sensitivity roll-off performance. We demonstrate: extended imaging range...
متن کاملRetinal, anterior segment and full eye imaging using ultrahigh speed swept source OCT with vertical-cavity surface emitting lasers
We demonstrate swept source OCT utilizing vertical-cavity surface emitting laser (VCSEL) technology for in vivo high speed retinal, anterior segment and full eye imaging. The MEMS tunable VCSEL enables long coherence length, adjustable spectral sweep range and adjustable high sweeping rate (50-580 kHz axial scan rate). These features enable integration of multiple ophthalmic applications into o...
متن کاملUltrahigh speed optical coherence tomography : New developments for ophthalmic imaging
Optical coherence tomography (OCT) is an imaging technique providing depthresolved, cross-sectional imaging of biological tissues with micrometer scale resolution. Recent advances in sensitivity and imaging speed have enabled the acquisition of three dimensional (3D) data sets. In ophthalmology, OCT has become an indispensible imaging tool for diagnosis of disease and monitoring therapy. While ...
متن کاملNoninvasive volumetric imaging and morphometry of the rodent retina with high-speed, ultrahigh-resolution optical coherence tomography.
PURPOSE To demonstrate high-speed, ultrahigh-resolution optical coherence tomography (OCT) for noninvasive, in vivo, three-dimensional imaging of the retina in rat and mouse models. METHODS A high-speed, ultrahigh-resolution OCT system using spectral, or Fourier domain, detection has been developed for small animal retinal imaging. Imaging is performed with a contact lens and postobjective sc...