Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study.

نویسندگان

  • D Steinmann
  • C A Stahl
  • J Minner
  • S Schumann
  • T Loop
  • A Kirschbaum
  • H J Priebe
  • J Guttmann
چکیده

BACKGROUND Double-lumen tubes (DLTs) are frequently used to establish one-lung ventilation (OLV). Their correct placement is crucial. We hypothesized that electrical impedance tomography (EIT) reliably displays distribution of ventilation between left and right lung and may thus be used to verify correct DLT placement online. METHODS Regional ventilation was studied by EIT in 40 patients requiring insertion of left-sided DLTs for OLV during thoracic surgery. EIT was recorded during two-lung ventilation before induction of anaesthesia and after DLT placement, and during OLV in the supine and subsequently in the lateral position. EIT measurements were made before and after verification of correct DLT placement by fibreoptic bronchoscopy (FOB). RESULTS EIT accurately displayed distribution of ventilation between left and right lung online. All cases (n=5) of initially misplaced DLTs in the contralateral right main bronchus were detected by EIT. However, EIT did not allow prediction of FOB-detected endobronchial cuff misplacement requiring DLT repositioning. Furthermore, after DLT repositioning, distribution of ventilation, as assessed by EIT, did not change significantly (all P>0.5). CONCLUSIONS This study demonstrates that EIT enables accurate display of left and right lung ventilation and, thus, non-invasive online recognition of misplacement of left-sided DLTs in the contralateral main bronchus. However, as distribution of ventilation did not correlate with endobronchial cuff placement, EIT cannot replace FOB in the routine control of DLT position.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A retrospective evaluation of the use of video-capable double-lumen endotracheal tubes in thoracic surgery.

OBJECTIVE The objective of this study was to evaluate whether the use of a video double-lumen tube reduced the need for fiberoptic bronchoscopy for (1) verification of initial tube placement and for (2) reverification of correct placement after repositioning for thoracotomy. DESIGN A single-center retrospective study. SETTING Thoracic surgery in a medical university hospital. PARTICIPANTS...

متن کامل

Measuring incisor-carina distance by fiberoptic bronchoscopy to guide the placement of a left-sided double-lumen endobronchial tube

The aim of this randomized observational study was to evaluate the effect of measuring the incisor-carina distance by fiberoptic bronchoscopy in guiding the placement of a left-sided double-lumen endobronchial tube. Fifty patients (American Society of Anesthesiologists class I-II) undergoing elective thoracic procedures requiring single-lung ventilation using a left-sided double-lumen endobronc...

متن کامل

Iatrogenic Left Main Bronchus Injury following Atraumatic Double Lumen Endotracheal Tube Placement

Tracheobronchial disruption is an uncommon but severe complication of double lumen endotracheal tube placement. The physical properties of a double lumen tube (large external diameter and length) make tracheobronchial injury more common than that associated with smaller single lumen endotracheal tubes. Here we present the case of an iatrogenic left main bronchus injury caused by placement of a ...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

Lung Separation in the Morbidly Obese Patient

Lung separation techniques in the morbidly obese patient undergoing thoracic or esophageal surgery may be at risk of complications during airway management. Access to the airway in the obese patient can be a challenge because they have altered airway anatomy, including a short and redundant neck, limited neck extension and accumulation of fat deposition in the pharyngeal wall contributing to di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 101 3  شماره 

صفحات  -

تاریخ انتشار 2008