Evaluation of Fetal Thyroid with 3D Gradient Echo T1-weighted MR Imaging
نویسندگان
چکیده
PURPOSE The characteristics of fetal thyroid on magnetic resonance (MR) imaging, including normal thyroid and disorders other than goiter have not been fully evaluated. Our aim was to assess fetal thyroid using three dimensional (3D) gradient echo (GRE) T1-weighted MR imaging and to examine the usefulness of this modality. MATERIALS AND METHODS The study included 27 3D GRE T1-weighted images from 26 fetuses. The largest possible region of interest (ROI) within the thyroid at the slice level depicting the thyroid was manually defined and three circular ROIs on neck muscle were manually defined on the image slices showing the highest signal intensity (SI) of the thyroid. Maximum and mean thyroid-to-muscle SI ratios (SIRs) were then calculated as SIR = maximum or mean thyroid SI/muscle SI. RESULTS The thyroid could not be identified in two cases. Fetal thyroid function was normal in 17 cases, and there were 7 cases of hypothyroidism (6 transient and 1 thyroid dysgenesis). There was no linear relationship between mean and maximum SIR and gestational age. The mean and maximum SIR in the cases of normal fetal thyroid were 1.85 ± 0.20 and 2.61 ± 0.39, and the mean and maximum SIR in fetal hypothyroidism were 1.58 ± 0.20 and 2.13 ± 0.37. Mean (P = 0.0088) and maximum (P = 0.0221) SIR values were significantly different between euthyroid and hypothyroid fetuses. CONCLUSION Thyroid SIR measurement provided useful information regarding fetal thyroid function.
منابع مشابه
T1-weighted magnetic resonance imaging sequence appropriate for the evaluation of the longitudinal relaxation effect of superparamagnetic iron oxide: a phantom study.
The goal of this study was to determine a T1-weighted magnetic resonance (MR) imaging sequence appropriate for evaluating the longitudinal relaxation effect of superparamagnetic iron oxide (ferumoxides) in a phantom study. An agarose phantom that included various concentrations of ferumoxides (0 - 0.5 mmol/l in 0.05 mmol/l increments) was examined for six types of T1-weighted imaging sequences ...
متن کاملQuantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging
Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...
متن کاملGd-DTPA-enhanced 3D MR imaging of cervical degenerative disk disease: initial experience.
PURPOSE To assess whether a single enhanced T1-weighted gradient echo volume sequence, with the appropriate reformatted images, could be equivalent to a more conventional 2D set of MR sequences for the evaluation of cervical extradural degenerative disk disease (bony canal and foraminal stenosis; disk herniation). MATERIALS AND METHODS Sixty-one patients evaluated for extradural degenerative ...
متن کاملSWI: Probe for neuroradiologists
Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...
متن کاملSWI: Probe for neuroradiologists
Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...
متن کامل