Noninvasive cardiac output measurement in orthostasis: pulse contour analysis compared with acetylene rebreathing.
نویسندگان
چکیده
We tested the reliability of noninvasive cardiac output (CO) measurement in different body positions by pulse contour analysis (CO(pc)) by using a transmission line model (K. H. Wesseling, B. De Wit, J. A. P. Weber, and N. T. Smith. Adv. Cardiol. Phys. 5, Suppl. II: 16-52, 1983). Acetylene rebreathing (CO(rebr)) was used as a reference method. Twelve subjects (age 21-34 yr) were studied: 1) six in whom CO(rebr) and CO(pc) were measured in the standing and 6 degrees head-down tilt (HDT) postures and 2) six in whom CO was measured in the 30 degrees HDT, supine, 30 degrees head up-tilt (HUT), and 70 degrees HUT postures on a tilt table. The CO(rebr)-to-CO(pc) ratio in (near) the supine position during rebreathing was used as the calibration factor for CO(pc) measurements. Calibrated CO(pc) (CO(cal sup)) consistently overestimated CO in the upright posture. The drop in CO with upright posture was underestimated by approximately 50%. CO(cal sup) and CO(rebr) values did not differ in the 30 degrees HDT position. Changes in the CO(rebr)-to-CO(pc) ratio are highly variable among subjects in response to a change in posture. Therefore, CO(pc) must be recalibrated for each subject in each posture.
منابع مشابه
Cardiac output monitoring: a contemporary assessment and review.
OBJECTIVE An increasing number of minimally or noninvasive devices are available to measure cardiac output in the critical care setting. This article reviews the underlying physical principles of these devices in addition to examining both animal and human comparative studies in an effort to allow clinicians to make informed decisions when selecting a device to measure cardiac output. DATA SO...
متن کاملValidation of a new spectrometer for noninvasive measurement of cardiac output
Acetylene is a blood-soluble gas and for many years its uptake rate during rebreathing tests has been used to calculate the flow rate of blood through the lungs ~normally equal to cardiac output! as well as the volume of lung tissue. A new, portable, noninvasive instrument for cardiac output determination using the acetylene uptake method is described. The analyzer relies on nondispersive IR ab...
متن کاملNoninvasive monitoring cardiac output using partial CO(2) rebreathing.
This article reviews use of partial carbon dioxide rebreathing devices to determine cardiac output and their application for hemodynamic monitoring in the ICU and operating room. The primary focus is on the NICO monitoring device. Compared with conventional cardiac output methods, these techniques are noninvasive, easily automated, and provide real-time and continuous cardiac output monitoring....
متن کاملMeasurement of cardiac output during exercise by open-circuit acetylene uptake.
Noninvasive measurement of cardiac output (QT) is problematic during heavy exercise. We report a new approach that avoids unpleasant rebreathing and resultant changes in alveolar PO(2) or PCO(2) by measuring short-term acetylene (C(2)H(2)) uptake by an open-circuit technique, with application of mass balance for the calculation of QT. The method assumes that alveolar and arterial C(2)H(2) press...
متن کاملSolubility characteristics of the ideal agent for measurement of cardiac output by soluble gas uptake methods.
Measurements of the rate of uptake of soluble gases such as nitrous oxide or acetylene has been used as the basis of a method of cardiac output estimation since 1912. Using theoretical models of single, multiple and rebreathing techniques of cardiac output measurement, we determined the effect of solubility in blood and lung tissue on the changes in the final expired concentration of the gas. D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 87 6 شماره
صفحات -
تاریخ انتشار 1999