Dosimetric Evaluation of a Flexible Dual Balloon-Constructed Applicator in Treating Anorectal Cancer
نویسندگان
چکیده
BACKGROUND AND PURPOSE To assess the dosimetric flexibility of a dual balloon brachytherapy applicator developed for the treatment of anorectal lesions. MATERIALS AND METHODS Different amounts of water were infused into the inner and outer balloon separately to study the asymmetrical distribution of the catheter, the radial distance of the active source channel to the inner surface of the global target volume , the space between the active source channels, and their dosimetric impact to target tissues and uninvolved rectum. RESULTS Increasing inner balloon volume directly increased both the space between the active source channels and the radial distance of the active source channel to the inner surface of the global target volume. The space between the active source channels and the percentage of global target volume received 150% or more of the prescribed dose to target had a strong inverse correlation (-0.881/ P = .007, -0.976/ P = .001, respectively) with the radial distance of the active source channel to the inner surface of the global target volume. Conformity index, dose to 2 cm3 of rectum, and total reference air kerma were strongly correlated with the radial distance of the active source channel to the inner surface of the global target volume, with values of 0.952 ( P = .001), 0.833 ( P = .015), and 0.922 ( P = .002), respectively. Percentage of global target volume received 150% or more of the prescribed dose was significantly correlated with the space between the active source channels (0.81/ P = .022), and conformity index was strongly inversely correlated with the space between the active source channels (-0.833/ P = .015). CONCLUSION The dual balloon-constructed Anorectal Applicator offers a flexible way to adjust the distances of the active source positions to the target in relation to uninvolved rectal wall. This flexibility simplifies planning which results in a highly conformal dose distribution to the target lesion while minimizing dose to normal rectal tissue.
منابع مشابه
Inflatable multichannel rectal applicator for adaptive image-guided endoluminal high-dose-rate rectal brachytherapy: design, dosimetric characteristics, and first clinical experiences
PURPOSE To investigate the dosimetric results and first clinical experiences with a new designed balloon applicator with adjustable catheters for endoluminal brachytherapy for patients with locally advanced rectal cancer not undergoing surgery. MATERIAL AND METHODS The applicator consists of an inflatable rectal balloon with six attached Foley catheters used as guidance for the inserted brach...
متن کاملCalculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP
Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...
متن کاملDosimetric evaluation of a novel high dose rate (HDR) intraluminal / interstitial brachytherapy applicator for gastrointestinal and bladder cancers
High dose rate (HDR) brachytherapy is one of the accepted treatment modalities in gastro-intestinal tract and bladder carcinomas. Considering the shortcoming of contact brachytherapy routinely used in gastrointestinal tract in treatment of big tumors or invasive method of bladder treatment, an intraluminal applicator with the capability of insertion into the tumor depth seems to be useful. This...
متن کاملDosimetric Comparison of Fixed and Flexible Geometry ICRT Applicators in Patients Treated for Carcinoma Cervix
In intracavitary radiotherapy (ICRT) for cancer cervix, applicator geometry has the potential to impact the doses to organs at risk (OARs) and the coverage of the target volume. At our centre two Varian made Fletcher-style applicator sets, namely defined (fixed) geometry and flexible geometry, are used for ICRT. In the present work, the two types of applicators were compared dosimetrically as p...
متن کاملDosimetric evaluation of multilumen intracavitary balloon applicator rotation in high‐dose‐rate brachytherapy for breast cancer
The objective of this work is to evaluate dosimetric impact of multilumen balloon applicator rotation in high-dose-rate (HDR) brachytherapy for breast cancer. Highly asymmetrical dose distribution was generated for patients A and B, depending upon applicator proximity to skin and rib. Both skin and rib spacing was ≤ 0.7 cm for A; only rib spacing was ≤ 0.7 cm for B. Thirty-five rotation scenari...