Purpose. Tube-related exposure is a known complication of glaucoma drainage device (GDD) surgery. Our objective is to report the early (approximately 1 year) tube exposure rate of implants covered with a keraSys (IOP Inc., Costa Mesa, CA, USA) tissue reinforcement graft. Patients and Methods. A retrospective, noncomparative, consecutive case series of 42 eyes with GDD implantation with keraSys patch grafts was performed. Main outcome measurements included patch-related complications: patch exposure, tube exposure, wound dehiscence, and patch migration. Results. Forty-two eyes were followed for an average of 15.24 ± 10.44 months (range 1.0-32.3 months). Four (10%) eyes experienced patch-related complications: two with exposure 8 months postoperatively, one with exposure 13 months postoperatively, and one with exposure 4 weeks postoperatively. Conclusion. The effectiveness of the keraSys patch graft is limited by the higher than expected early exposure rate found in this case series. These results should be confirmed in other studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery

Purpose. To report a new technique for anterior placement of tubes for glaucoma drainage devices to reduce the risk of tube erosions. Methods. Retrospective review of select cases of Ahmed Valve surgery combined with the novel method of a limbal-based scleral flap covered by a scleral patch graft to cover the tube at the entrance through the limbus. Intraoperative and postoperative illustration...

متن کامل

Glaucoma Surgery in Pregnancy: A Case Series and Literature Review

AbstractGlaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum t...

متن کامل

New Technique of Exposed Glaucoma Drainage Tube Repair: Report of a Case.

We present the case of successful repair of an exposed glaucoma drainage tube by cornea graft fixation with tissue adhesive, and without subsequent coverage by adjacent conjunctiva or donor tissues. Patient with history of keratoglobus with thin cornea and sclera, and phthisical contralateral eye, underwent three unsuccessful corneal grafts followed by Boston type 1 keratoprosthesis in the righ...

متن کامل

Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma

Glaucoma drainage implants (GDIs) are used to treat paediatric glaucoma resistant to conventional medical and surgical treatment, achieving good intraocular pressure (IOP) control and long-term success. Late endophthalmitis is a rare complication that may develop following GDI surgery. A 17-year-old male presented with acute endophthalmitis 2 years after Ahmed glaucoma valve implantation with p...

متن کامل

Conjunctival inclusion cyst following repair of tube erosion in a child with aphakic glaucoma, leading to endophthalmitis

INTRODUCTION Glaucoma in aphakia is a major long term complication following congenital cataract surgery. Implantation of glaucoma drainage device provides an effective approach to manage refractory paediatric glaucoma. However implant surgery in young individuals is not free of complications. The prompt detection and management of tube erosion is of utmost importance to prevent devastating seq...