Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.
نویسندگان
چکیده
Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included in this prospective randomized trial. Twenty eyes underwent IOL master and 20 eyes had aplanation ultrasound biometry. There were included only eyes with age-related cataract and postoperative natural visual acuity (VA) 0.7. Visual acuity was performed 6 weeks after cataract surgery. After 6 weeks best natural visual acuity were 0.9 (± 0.1) in IOL-Master group and 0.85 (± 0.15) in ultrasound biometry. The postoperative mean absolute refractive error was 0.75 (± 0.5) D for ultrasound biometry and 0.50 (± 0.50) D for IOL-Master. Optical biometry with the IOL-Master proved to be slightly more accurate than ultrasound biometry for IOL power calculation.
منابع مشابه
Accuracy of intraocular lens power calculations using the Zeiss IOL master. A prospective study.
PURPOSE Partial Coherence Interferometry (PCI) is a fast, noncontact method to calculate lens implant power for cataract surgery. It has been reported as a potentially more accurate method than ultrasound biometry. Prospective study of the refractive outcomes of a consecutive series of patients undergoing phacoemulsification surgery with preoperative biometry by both ultrasound A-scan and PCI. ...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملThe effect of ocular biometric factors on the accuracy of various IOL power calculation formulas
BACKGROUND To evaluate how differences in ocular biometry affects the Hoffer Q, Holladay 1, SRK/T, and Haigis intraocular lens power calculation formulae predictions. METHODS This study was performed on 91 eyes of 91 patients who underwent uneventful cataract surgery. Ocular biometry values were measured using the IOL Master 500, and intraocular lens (IOL) power was calculated using the Haigi...
متن کاملRefractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation
PURPOSE To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. METHODS Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refract...
متن کاملLimitations of Intraoperative Aphakic Refraction Technique for Intraocular Lens Power Calculation
Intraocular lens (IOL) power calculations are known to be difficult in eyes that have had corneal refractive surgery and several methods have been proposed to estimate IOL power. Among the methods not requiring preoperative data, the apahakic refraction technique has been successfully used to calculate IOL power in post-refractive cases and other conditions that cause unreliability in standard ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Collegium antropologicum
دوره 39 1 شماره
صفحات -
تاریخ انتشار 2015