Efficacy evaluation of syringe pump developed for continuous drug infusion

نویسندگان

  • Bongsu Jung
  • Kwang-Suk Seo
  • Suk Jin Kwon
  • Kiyoung Lee
  • Suyong Hong
  • Hyounsoon Seo
  • Gi-Young Kim
  • Geun-Mook Park
  • Juhee Jeong
  • Soowon Seo
چکیده

BACKGROUND In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be received from the approving agency based on such test results. METHODS The authors of the present study developed a novel syringe pump and performed efficacy evaluation by testing its infusion speed at 1 and 25 ml/h, and infusion performance testing at 2 and 24 h. Moreover, performance evaluation was conducted by comparing the novel pump to an existing pump with the infusion speed varied from 1 to 5 ml/h. RESULTS In the efficacy testing on the newly developed syringe pump, infusion with the infusion speed initially set to 1 ml/h resulted in infusion speeds of 1.00 and 0.99 ml/h in the 2- and 24-h assessment, respectively. Changing the infusion speed setting to 25 ml/h resulted in an infusion speed of 25.09 and 23.92 ml/h in the 2- and 24-h assessment, respectively. These results show no significant differences when compared with other commercially available pumps. CONCLUSIONS The efficacy testing of the newly developed syringe pump showed the accuracy to be within tolerance. Based on these findings, we believe that the newly developed syringe pump is suitable for clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accurate continuous drug delivery at low infusion rate with a novel microvolumetric infusion pump (MVIP): pump design, evaluation and comparison to the current standard.

Infusion devices for continuous and precise drug administration are indispensable tools in anaesthesia and critical care medicine. Problems such as start-up delays, non-continuous flow and susceptibility to hydrostatic pressure changes at low infusion rates resulting in accidental bolus release or prolonged flow interruption are inherent to current infusion technology. In order to improve preci...

متن کامل

Standard drug concentrations and smart-pump technology reduce continuous-medication-infusion errors in pediatric patients.

OBJECTIVE To determine if combining standard drug concentrations with "smart-pump" technology reduces reported medication-infusion errors. DESIGN Preintervention and postintervention comparison of reported medication errors related to infusion therapies during the calendar years 2002 and 2003. SETTING A 242-bed university-affiliated tertiary pediatric hospital. INTERVENTION Change in cont...

متن کامل

Smart syringe pumps for drug infusion during dental intravenous sedation

Dentists often sedate patients in order to reduce their dental phobia and stress during dental treatment. Sedatives are administered through various routes such as oral, inhalation, and intravenous routes. Intravenous administration has the advantage of rapid onset of action, predictable duration of action, and easy titration. Typically, midazolam, propofol or dexmedetomidine are used as intrav...

متن کامل

Preparing Drugs for Infusion Via Syringe Pump: A Key Step to Ensure Homogeneous Concentration.

OBJECTIVE Preparation of drug solutions used with electronic syringe infusion pumps plays a crucial role in the delivery of an accurate drug concentration. Is there a correlation between drug concentrations during syringe pump infusion and preparation protocols? METHOD Norepinephrine, insulin, and sufentanil were prepared in 3 different ways: (1) the drug was taken from the vial, then the sol...

متن کامل

Computer control of drug delivery by continuous intravenous infusion: bridging the gap between intended and actual drug delivery.

BACKGROUND Intravenous drug infusion driven by syringe pumps may lead to substantial temporal lags in achieving steady-state delivery at target levels when using very low flow rates ("microinfusion"). This study evaluated computer algorithms for reducing temporal lags via coordinated control of drug and carrier flows. METHODS Novel computer control algorithms were developed based on mathemati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016