CLINICAL SCIENCE Posterior corneal topographic changes after partial flap during laser in situ keratomileusis
نویسندگان
چکیده
Aim: To study the posterior corneal topographic changes in eyes with partial flaps during laser assisted in situ keratomileusis (LASIK). Methods: Case records of 16 patients, who had partial flap in one eye during LASIK (group 1) and uncomplicated surgery in the other eye (group 2), were studied. Following occurrence of partial flap intraoperatively, laser ablation was abandoned in all the eyes. A 160/180 μm flap was attempted during the initial procedure using the Hansatome microkeratome (Bausch & Lomb Surgicals, Munich, Germany). LASIK surgery in all cases was performed using a 180 μm plate, at the mean interval of 4.16 (SD 1.5) months following the initial procedure. None of the eyes had intraoperative complication during LASIK. Relative posterior corneal surface elevation above the best fit sphere (BFS) before the initial procedure, before, and after LASIK were compared using the Orbscan slit scanning corneal topography/pachymetry system. Results: Posterior corneal elevation was comparable in the two groups, both preoperatively (group 1; 16.4 (4.8) μm, group 2; 16.1 (4.8) μm) and after final surgery (group 1; 57.2 (15.6) μm, group 2; 54.3 (13.1) μm). In group 1 after occurrence of partial flap, the posterior corneal elevation was 16.9 (4.4) μm, and this increase was not significant statistically (p=0.4). On multiple linear regression analysis, residual bed thickness (p<0.001) was independently the significant determinant of final posterior corneal elevation in both groups. Conclusion: The inadvertent occurrence of partial flap during LASIK procedure does not contribute to the increase in posterior corneal elevation.
منابع مشابه
Posterior corneal topographic changes after partial flap during laser in situ keratomileusis.
AIM To study the posterior corneal topographic changes in eyes with partial flaps during laser assisted in situ keratomileusis (LASIK). METHODS Case records of 16 patients, who had partial flap in one eye during LASIK (group 1) and uncomplicated surgery in the other eye (group 2), were studied. Following occurrence of partial flap intraoperatively, laser ablation was abandoned in all the eyes...
متن کاملNoncontact measurements of central corneal epithelial and flap thickness after laser in situ keratomileusis.
PURPOSE To investigate the changes in the epithelium and flap after laser in situ keratomileusis (LASIK), when measured with optical coherence tomography (OCT). METHODS Twenty-eight eyes of 14 patients (age: 39.9 +/- 8.6 years) underwent LASIK. The central thickness of corneal epithelium and flap were measured with a real-time 1310 nm OCT 1 day, 1 week, and 1 month after surgery. A custom sof...
متن کاملTopography-guided neutralization technique for the management of flap complication in laser in situ keratomileusis
A 29-year-old male was referred following a flap loss after the creation of a thin, irregular flap with a visual acuity of logMAR 0.1 with -2.0 DS-2.75 DC × 175°. Corneal topography and anterior segment optical coherence tomography revealed an irregular corneal curvature and epithelial profile. Phototherapeutic keratectomy (PTK) followed by Topography - Guided Custom Ablation Treatment (TCAT), ...
متن کاملArc-scanning very high-frequency digital ultrasound for 3D pachymetric mapping of the corneal epithelium and stroma in laser in situ keratomileusis.
PURPOSE To test and demonstrate measurement precision, imaging resolution, 3D thickness mapping, and clinical utility of a new prototype 3D very high-frequency (VHF) (50 MHz) digital ultrasound scanning system for corneal epithelium, flap, and residual stromal thickness after laser in situ keratomileusis (LASIK). METHODS VHF ultrasonic 3D data was acquired by arc-motion, meridional scanning w...
متن کاملFlap tearing during lift-flap laser in situ keratomileusis retreatment.
A flap tear occurred during laser in situ keratomileusis (LASIK) retreatment using a flap-lifting technique in 1 eye of 2 patients 4 to 5 months after the primary procedure. In the first case, the tear occurred in a decentered, standard thickness flap (168 mum) in a location close to the corneal limbus and limbal vessels. In the second case, the tear occurred in a well-centered thin flap (116 m...
متن کامل