Radiovisiography versus Conventional Radiography for Estimation of Canal Length: an in Vitro Study
نویسنده
چکیده
The aim of this study was to compare the accuracy of the Radiovisiography (RVG) with conventional Radiographic in canal length estimation in vitro for root canal treatment. Forty-single-rooted teeth were endodontically assessed and working lengths were determined using both conventional intra-oral dental film and Radiovisiography (RVG) 1R1X 70 intra-oral x-ray system. Measurement assessment was done by two observers. The actual pre-measured lengths of the files and roots were unknown to the observers. Result showed that both conventional radiography and RVG showed a significant greater length than the true length. These differences are statistically significant (P<0.05) but of limited clinical significance. In conclusion RVG is of equal value to conventional radiography in root canal length determination. It was concluded that RVG has the advantage of low radiation dose and rapid image production and recommended to be used during endodontic therapy.
منابع مشابه
In Vitro Comparative Study of the Working Length Determination with Radiovisiography and Conventional Radiography in Dilacerated Canals
Introduction: The aim of this study was to compare digital and conventional radiography in determining the working length of dilacerated canals.Methods: Thirty nine human extracted single-rooted teeth with root curvature more than 35 degrees were included in this study. After access preparation, a file was inserted into the canal and advanced until the file tip was visualized at the foramen. Wi...
متن کاملIn Vitro Comparative Study of the Working Length Determination with Radiovisiography and Conventional Radiography in Dilacerated Canals
Introduction: The aim of this study was to compare digital and conventional radiography in determining the working length of dilacerated canals. Methods: Thirty nine human extracted single-rooted teeth with root curvature more than 35 degrees were included in this study. After access preparation, a file was inserted into the canal and advanced until the file tip was visualized at the foramen. W...
متن کاملبررسی و ارزیابی رادیوویزیوگرافی در تعیین طول کارکرد کانال و مقایسه آن با رادیوگرافی معمولی
One of the major factors in a successful root canal therapy is the determination of root length before canal preparation. Radiography has been proved to be useful in this case, but nowadays for reducing radiation, radiovisiography has been recommended. The aim of this study was comparing conventional radiography (CR) with radiovisiography (RVG) in determination of canal length. 101 anterior and...
متن کاملComparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study
Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...
متن کاملComparison of working length determination using apex locator, conventional radiography and radiovisiography: an in vitro study.
AIM The purpose of this study was to compare the working length determination done using three methods, namely, apex locator (Foramatron D-10, Parkell), radiovisiography (Planmeca) and conventional radiography (Prostyle intra, Planmeca). MATERIALS AND METHODS In this experiment, to determine the working length, 35 single-rooted teeth were selected and each tooth was subjected to all the three...
متن کامل