Mini titanium plates; hearkening the end of non-rigid cranial bone flap fixation
نویسندگان
چکیده
BACKGROUND AND OBJECTIVE Craniotomy bone flaps should be replaced for both cosmetic and protective purposes. Different methods are available commercially. The aim of this study was to assess outcome of bone flap fixation using mini titanium plates and screws. METHODS Between March, 2011 and March, 2014, 71 patients underwent cranial bone flap fixation with mini titanium plates and screws after craniotomy and excision of supratentorial lesions at Combined Military Hospital, Peshawar. There were 42 males and 30 females with a mean age of 40.07. All patients had supratentorial lesions. Intracranial lesion size ranged from 3 cm by 2 cm to 7 cm by 5 cm. The changes of local incision and general condition were observed. RESULTS Subcutaneous effusion occurred in two patients. One patient developed a mild postoperative wound infection. CT scan showed good repositioning of the flap and edge to edge apposition at two weeks after operation. All the patients were followed up for 12 months post operatively. Skull had good appearance without any discharge and, local deformity or effusion. Repeat CT/MRI showed no subsidence or displacement of cranial flap or artifacts. CONCLUSION Mini titanium plate and screw fixation of cranial flaps is a simple, cost effective and safe option for repositioning and immediate stability as compared to traditional sutures.
منابع مشابه
Mini titanium plates and screws for cranial bone flap fixation; an experience from Pakistan
The biocompatibility and osseointegrative qualities of the element titanium have allowed its extensive use medical science especially Orthopedics and Neurosurgery, effectively replacing its predecessor, steel. Historically, nonabsorbable sutures were used to anchor the bone flap following a craniotomy but have been associated with functional and cosmetic defects as well as nonunion and failure ...
متن کاملThree Dimensional Titanium Mini Plates in Management of Mandibular Fractures
The treatment of mandibular fractures has evolved from various forms of wiring, splinting, intermaxillary fixation, rigid fixation, compression plates, and mini plates. But in all this circumastances there is a chance of potential infection and malunion in mandibular fracture site. So in our study we used three dimensional titanium miniplates to stabilize the mandibular fracture site. The 3 D t...
متن کاملUse of bioabsorbable plates for cranial fixation.
LactoSorb fixation plates are made of a bioabsorbable polymer (82% poly-L-lactic acid and 18% polyglycolic acid), and the strength is not inferior to titanium plates. LactoSorb has been used in the fields of pediatric neurosurgery and facial plastic surgery. Cranial fixation in craniotomy is mostly performed using titanium plates and clamps, but there are issues with esthetics and artifacts on ...
متن کاملSS and titanium mini plate fixation in fracture of mandible
INTRODUCTION The development and application of bone plating to the maxillofacial skeleton has revolutionized the operative management of trauma and reconstructive surgery. Non compression monocortical miniplate fixation of the mandible is an accepted and reliable method for providing semi rigid internal fixation. In the 21 st century many other systems have been introduced such as locking plat...
متن کاملFixation of mandibular osteotomies: comparison of locking and nonlocking hardware.
BACKGROUND : The outcome of patients undergoing rigid plate fixation of symphyseal mandibular osteotomies for exposure, resection, and reconstruction of tumors in the oral cavity or oropharynx was analyzed to determine the impact of hardware selection on complications. METHODS : Forty-five patients underwent titanium plate rigid internal fixation of mandibular osteotomies during cancer resect...
متن کامل