A quantitative evaluation of fluid leakage around a polyvinyl chloride tapered endotracheal tube cuff using an in-vitro model
نویسندگان
چکیده
INTRODUCTION This study was designed to quantitatively evaluate the sealing effect of a polyvinyl chloride tapered endotracheal tube cuff and to compare the tapered cuff with cylindrical endotracheal tube cuffs using an in vitro viscous fluid model. METHODS Five types of 8.0 mm inner diameter endotracheal tubes (TaperGuard, PortexSacett, PortexSoftseal, Sheridan HVT, Sheridan CF) were fixed in vertically placed 20mm internal diameter acrylic tubes. The cuffs were inflated to 25 mmHg pressure and water was added to the top of the cuff. The amount of water leaking around the cuff at five minutes was measured. Afterwards a viscous fluid was poured above the cuff and the amount of fluid passing around the cuff at five minutes and four hours was measured. Each determination was repeated five times and the data analyzed. RESULTS The median (range) amount (ml) of dyed water passing around the cuff at 5 minutes was TaperGuard tube 0 (0-0.2), PortexSacett 81.1 (44.6-107.9), PortexSoftseal 95.4 (91.4-113.7), Sheridan HVT 46.5 (32.7-74.6) and Sheridan CF 52.6 (31.9-62.2), suggesting that TaperGuard significantly (P<0.05) reduced fluid leakage. The viscous fluid leakage at 5 minutes was not significantly different among the groups while the amount of leaked viscous fluid at 4 hours was 0.2 (0-1.1) for the TaperGuard, 57.6 (11.9-117.4) for the PortexSacett, 23.2 (13.8-33.0) for the PortexSoftseal, 5.5 (2.7-15.4) for the Sheridan HVT and 5.6 (1.8-7.9) for the Sheridan CF. CONCLUSION An endotracheal tube with a tapered polyvinyl chloride cuff had significantly less fluid leakage compared to four tubes with cylindrical cuffs.
منابع مشابه
Comparison of a novel lycra endotracheal tube cuff to standard polyvinyl chloride cuff and polyurethane cuff for fluid leak prevention.
BACKGROUND A high-volume low-pressure endotracheal tube (ETT) cuff forms folds along its contact with the trachea, allowing mucus leakage into the lungs. We developed a thin-walled ETT cuff made of Lycra polyurethane. METHODS In vitro, we tested 6 of each of the new prototype Lycra cuff, the Mallinkrodt Hi-Lo ETT (polyvinyl chloride cuff), and the Kimberly-Clark Microcuff ETT (polyurethane cu...
متن کاملRESPIRATION AND THE AIRWAY Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study
Key points † Optimizing tracheal sealing is of clinical interest: fluid leakage past the tube cuff plays an important role in the pathogenesis of VAP. † Tapered shaped tube cuff offering a sealing zone with reduced folds and channels is a new strategy to minimize fluid leakage past the tracheal tube cuff. † Tracheal tube cuffs made from PVC show much more and faster fluid leakage than cuffs mad...
متن کاملAssessment of aspiration risk from dynamic modulation of endotracheal tube cuff pressure.
OBJECTIVES/HYPOTHESIS To assess the risk of aspiration using a novel valve circuit that dynamically modulates endotracheal tube cuff pressure during the ventilatory cycle using bench and live animal models. STUDY DESIGN Animal model. METHODS The bench model consisted of a cuffed endotracheal tube inserted into an artificial trachea. Leakage of liquid around the cuff was measured after 4 hou...
متن کاملComparison of prophylactic effects of polyurethane cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes on ventilator-associated pneumonia.
Because microaspiration of contaminated supraglottic secretions past the endotracheal tube cuff is considered to be central in the pathogenesis of pneumonia, improved design of tracheal tubes with new cuff material and shape have reduced the size and number of folds, which together with the addition of suction ports above the cuff to drain pooled subglottic secretions leads to reduced aspiratio...
متن کاملThe value of polyurethane-cuffed endotracheal tubes to reduce microaspiration and intubation-related pneumonia: a systematic review of laboratory and clinical studies
BACKGROUND When conventional high-volume, low-pressure cuffs of endotracheal tubes (ETTs) are inflated, channel formation due to folds in the cuff wall can occur. These channels facilitate microaspiration of subglottic secretions, which is the main pathogenic mechanism leading to intubation-related pneumonia. Ultrathin polyurethane (PU)-cuffed ETTs are developed to minimize channel formation in...
متن کامل