Epidemiological data on airborne contact dermatitis - results of the IVDK.

نویسندگان

  • Kristine Breuer
  • Wolfgang Uter
  • Johannes Geier
چکیده

BACKGROUND Airborne contact dermatitis (AirbCD) is not uncommon, according to a large number of published case reports and review articles. Epidemiological data on AirbCD based on larger clinical samples have not yet been published. OBJECTIVES To investigate demographic characteristics and patch test reactivity in patients diagnosed with both occupational and non-occupational AirbCD. METHODS A retrospective analysis of data from the Information Network of Departments of Dermatology (IVDK), 1994-2013, including 201 344 consecutively patch tested patients, was performed. RESULTS One thousand two hundred and three patients (0.6%) were diagnosed with AirbCD, 421 (35.0%) of these with an occupational background. Occupational dermatitis and face involvement were more prevalent than in patients without AirbCD (n = 200 141). Sensitization to epoxy resin and sensitization to methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) were significantly associated with AirbCD, and there was a trend for sensitization to Compositae mix and/or sesquiterpene lactone mix to be associated with AirbCD. Adhesives, plastics, construction materials, paints and varnishes in occupational cases, and plants in non-occupational cases, were the most commonly documented culprit product categories. CONCLUSIONS AirbCD is more common in patients with occupational dermatitis than in patients with non-occupational dermatitis. In our clinical sample, components of epoxy resin systems, MCI/MI and Compositae allergens were the most important contact allergens associated with AirbCD. Patch testing with additional allergens is important.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Periorbital dermatitis: causes, differential diagnoses and therapy.

Periorbital dermatitis is common and frequently difficult to treat. Patients with periorbital dermatitis often suffer severely because their disease is in such a visible location. Because of the variety of clinical appearance, the differential diagnostic considerations are often difficult. We examined the causes of periorbital dermatitis and compared the data of 88 patients from the Department ...

متن کامل

Occupational contact allergy caused by rubber gloves--nothing has changed.

BACKGROUND Allergic contact dermatitis caused by rubber gloves is not infrequent, and has almost exclusively been attributed to contact sensitization to accelerators. Thiurams have been the most frequent allergens, followed by dithiocarbamates. OBJECTIVES To describe the current allergen pattern in patients with occupational allergic contact dermatitis caused by rubber gloves. METHODS This ...

متن کامل

Contact allergy to ingredients of hair cosmetics - a comparison of female hairdressers and clients based on IVDK 2007-2012 data.

BACKGROUND Cosmetics for bleaching, waving/relaxing and dyeing hair contain well-known allergens, leading to a substantial number of cases of allergic contact dermatitis. OBJECTIVE To compare the frequency of important contact allergens (i) between two distinct groups of exposed patients, and (ii) with previous surveillance data. METHODS On the basis of data collected by the Information Net...

متن کامل

Is hydroxyisohexyl 3-cyclohexene carboxaldehyde sensitization declining in central Europe?

In several studies conducted during the last decade, the synthetic fragrance hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC; CAS 31906-04-4) has been shown to be a frequent sensitizer, with a prevalence of >2% among patients tested (1–6). Recent publications, however, have reported prevalences of sensitization of <2%, both in Denmark (7) and in Germany (8). However, in the most recent re-an...

متن کامل

Patch testing with fragrance mix II: results of the IVDK 2005-2008.

BACKGROUND The fragrance mix (FM I), established in 1977, detects the majority, but not all cases of contact allergy to fragrances. Based on European research 2002/2003, fragrance mix II (FM II) was developed to supplement FM I. In 2005, the German Contact Dermatitis Research Group (DKG) added FM II to their baseline series. OBJECTIVES To evaluate reactions to FM II and its constituents in ro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contact dermatitis

دوره 73 4  شماره 

صفحات  -

تاریخ انتشار 2015