Activated partial thromboplastin time versus antifactor Xa heparin assay in monitoring unfractionated heparin by continuous intravenous infusion.

نویسندگان

  • David J Guervil
  • Amy F Rosenberg
  • Almut G Winterstein
  • Neil S Harris
  • Thomas E Johns
  • Marc S Zumberg
چکیده

BACKGROUND Unfractionated heparin (UFH) has been used clinically for 5 decades. Despite being a cornerstone of anticoagulation, UFH is limited by its unpredictable pharmacokinetic profile, which makes close laboratory monitoring necessary. The most common methods for monitoring UFH are the activated partial thromboplastin time (aPTT) and antifactor Xa heparin assay (anti-Xa HA), but both present challenges, and the optimal method to monitor UFH remains unclear. OBJECTIVE To compare the performance of the aPTT with the anti-Xa HA for efficiency and safety of monitoring intravenous UFH infusions. METHODS This was a single-center, retrospective, observational cohort study conducted in an 852-bed academic medical center. RESULTS One hundred patients receiving intravenous UFH for a variety of indications were enrolled in the study; 50 were assigned to each group. The mean (SD) time to achieve therapeutic anticoagulation was significantly less in the anti-Xa HA group compared with the aPTT group (28 [16] vs 48 [26] hours, p < 0.001). In addition, a greater percentage of anti-Xa HA patients compared to aPTT patients achieved therapeutic anticoagulation at 24 hours (OR 3.5; 95% CI 1.5 to 8.7) and 48 hours (OR 10.9; 95% CI 3.3 to 44.2). Patients in the anti-Xa HA group also had more test values within the therapeutic range (66% vs 42%, p < 0.0001). A significant difference was seen between the 2 groups in the number of aPTT or anti-Xa HA tests performed per 24 hours (p < 0.0001) and number of infusion rate changes per 24 hours (p < 0.01), both favoring the anti-Xa HA group. CONCLUSIONS Monitoring intravenous UFH infusions with the anti-Xa HA, compared to the aPTT, achieves therapeutic anticoagulation more rapidly, maintains the values within the goal range for a longer time, and requires fewer adjustments in dosage and repeated tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concordance between Activated Partial Thromboplastin Time and Antifactor Xa Assay for Monitoring Unfractionated Heparin in Hospitalized Hyperbilirubinemic Patients.

BACKGROUND Activated partial thromboplastin time (aPTT) and antifactor Xa (anti-Xa) monitoring methods for unfractionated heparin (UFH) often disagree. The extent of discordance for those with elevated bilirubin remains unclear. Our objective was to evaluate concordance between activated aPTT and anti-Xa methods for hyperbilirubinemic patients on UFH. METHODS This was a retrospective cohort s...

متن کامل

Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy

BACKGROUND Unfractionated heparin (UFH) has unstable pharmacokinetics and requires close monitoring. The activated partial thromboplastin time (aPTT) test has been used to monitor UFH therapy for decades in Korea, but its results can be affected by numerous variables. We established an aPTT heparin therapeutic range (HTR) corresponding to therapeutic anti-Xa levels for continuous intravenous UF...

متن کامل

Comparison of routine laboratory measures of heparin anticoagulation for neonates on extracorporeal membrane oxygenation.

Our objective was to determine the best measure of heparin anticoagulation in neonatal patients on extracorporeal membrane oxygenation. Activated clotting time (ACT), activated partial thromboplastin time (aPTT), and antifactor Xa levels, along with corresponding heparin infusion rates and heparin bolus volumes, were collected from neonates receiving ECMO at our institution from 2008 to 2013. A...

متن کامل

Heparin Resistance During and Post-Intravenous Nitroglycerin Infusion

      Nitroglycerin has been reported to reduce activated partial thromboplastin time (aPTT) values in patients treated with concurrent heparin and nitroglycerin. However, studies have yielded conflicting results. To determine whether intravenous nitroglycerin alters the anticoagulant effect of heparin, we prospectively evaluated twenty patients admitted for coronary angioplasty by measurin...

متن کامل

Challenges in variation and responsiveness of unfractionated heparin.

Unfractionated heparin (UFH) has been in clinical use for more than half a century. Despite its undoubted contribution to the treatment and prevention of thrombosis, heparin is significantly limited by its variable biochemical composition and unpredictable pharmacokinetics. The situation is compounded by the fact that methods for monitoring heparin do not necessarily reflect its therapeutic eff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of pharmacotherapy

دوره 45 7-8  شماره 

صفحات  -

تاریخ انتشار 2011