SCIENTIFIC CORRESPONDENCE Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension

نویسندگان

  • O Schwenn
  • R Troost
  • A Vogel
  • F Grus
  • S Beck
  • N Pfeiffer
چکیده

Background/aim: Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open angle glaucoma (POAG) and high IOP, normal tension glaucoma (NTG), and ocular hypertension (OHT). Furthermore, the authors examined whether there were any correlations with blood pressure. Methods: 80 subjects were divided into four groups (n=20): 20 patients each with POAG, NTG, and OHT and 20 volunteers without any ocular pathology except for cataract served as a control group. Results: The OPA of the POAG group was not statistically significant different from the control group and from the OHT group. However, OPA was statistically significant lower (p<0.01) in the NTG group compared with all other groups. The OPA of the OHT group was slightly higher compared to the healthy volunteers (p=0.09) and to the POAG patients (p=0.09). No statistically significant correlations with blood pressure could be detected. A logistic regression model was established which identified OPA as an independent risk factor for NTG. Conclusions: The study demonstrated a decrease in OPA of patients suffering from NTG. Thus, measuring of OPA by the SmartLens dynamic observing tonometer could be helpful in the detection of NTG patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Ocular pulse amplitude in patients with open-angle glaucoma, normal-tension glaucoma, and ocular hypertensionby dynamic observing tonometry].

PURPOSE The aim of this study was to compare the ocular pulse amplitude (OPA) in patients with different types of glaucoma, and also to evaluate the usefulness of OPA for the elucidation of normal-tension glaucoma (NTG). OPA is thought to reflect choroidal circulation. SUBJECTS Sixty-six patients with normal-tension glaucoma (NTG), 52 patients with primary open angle glaucoma (POAG), 42 with ...

متن کامل

Ocular pulse amplitude in patients with open angle glaucoma, normal tension glaucoma, and ocular hypertension

Background/aim: Intraocular pressure (IOP) is not a fixed constant value but rather has pulsatile components associated with cardiac action. The SmartLens dynamic observing tonometer (odc, Ophthalmic Development Company AG, Zurich, Switzerland) can measure and record simultaneously IOP and ocular pulse amplitude (OPA). It was the aim of this study to evaluate OPA in patients with primary open a...

متن کامل

مقایسه تاثیر تیمولول و بتاکسولول بر کاهش فشار داخل چشمی و عوارض موضعی و سیستمیک آنها

Background and purpose: This is a study to compare the efficacy and side effects of betaxolol and timolol in lowering the IOP of primary open angle glaucoma or ocular hypertension. Materials and Methods: This Double-blind randomized cross-over clinical trial was conducted on 29 eyes of 20 patients with primary open angle glaucoma or ocular hypertension. Each patient received timolol 0.5% a...

متن کامل

Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension.

BACKGROUND/AIMS Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter ...

متن کامل

Ocular pulse amplitude in different types of glaucoma using dynamic contour tonometry: Diagnosis and follow-up of glaucoma

The aim of the present study was to compare the ocular pulse amplitude (OPA) in patients with different types of glaucoma using dynamic contour tonometry (DCT), to evaluate ocular and systemic factors associated with the OPA and to verify whether OPA measured by DCT is an independent predictor for glaucoma diagnosis. A total of 217 eyes of 217 participants in the following five groups were incl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002