BACKGROUND/AIMS To prevent the transmission of pathogens by endoscopes, following established reprocessing guidelines is critical. An ideal reprocessing step is simple, fast, and inexpensive. Here, we evaluated and compared the efficacy and safety of two disinfectants, a tertiary amine compound (TAC) and ortho-phthalaldehyde (OPA). METHODS A total of 100 colonoscopes were randomly reprocessed using two same automated endoscope reprocessors, according to disinfectant. The exposure time was 10 minutes for 0.55% OPA (Cidex® OPA, Johnson & Johnson) and 5 minutes for 4% TAC (Sencron2®, Bab Gencel Pharma & Chemical Ind. Co.). Three culture samples were obtained from each colonoscope after reprocessing. RESULTS A total of nine samples were positive among the 300 culture samples. The positive culture rate was not statistically different between the two groups (4% for OPA and 2% for TAC, P=0.501). There were no incidents related to safety during the study period. CONCLUSIONS TAC was non-inferior in terms of reprocessing efficacy to OPA and was safe to use. Therefore, TAC seems to be a good alternative disinfectant with a relatively short exposure time and is also less expensive than OPA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison on the Efficacy of Disinfectants Used in Automated Endoscope Reprocessors: PHMB-DBAC versus Orthophthalaldehyde

BACKGROUND/AIMS Since endoscopes are reusable apparatus classified as semicritical item, thorough reprocessing to achieve high-level disinfection is of utmost importance to prevent spread of infection. To improve disinfection efficacy and safety, disinfectants and endoscope reprocessors are continuously evolving. This study aimed to compare the efficacy of the combination of polyhexamethylenebi...

متن کامل

Susceptibility of HPV16 and 18 to high level disinfectants indicated for semi‐critical ultrasound probes

Ultrasound probes used in endocavitary procedures have been shown to be contaminated with high-risk HPV after routine use and HPV is also known to be resistant to some high level disinfectants (HLDs). This study compared efficacy of two leading ultrasound probe HLD methods; liquid ortho-phthalaldehyde (Cidex® OPA) and an automated device using sonicated hydrogen peroxide (trophon® EPR) against ...

متن کامل

A randomised, single-blind comparison of high-level disinfectants for flexible nasendoscopes.

OBJECTIVES To compare the microbiological efficacy, turnaround time, cost, convenience, and patient and user tolerance of Tristel Trio Wipes, PeraSafe solution and Cidex OPA solution for the high-level disinfection of flexible nasendoscopes. METHODS Flexible nasendoscopes were used in routine clinical encounters. They were then disinfected with one of the three disinfectant methods. Surveilla...

متن کامل

An exception to the rule "no association between antibiotic resistance and decreased disinfectant microbicidal efficacy": Orthophthalaldehyde (OPA) and Pseudomonas aeruginosa isolated from ICU and paraplegic patients

BACKGROUND Antibiotic resistance and decreased susceptibility to disinfectants are not usually associated in microorganisms, but we have found an exception to this rule: P. aeruginosa versus orthophthalaldehyde (OPA). METHODS Bactericidal effect of OPA was measured at 10 minutes on endodoncy files contaminated with an ATCC strain (control) or 206 strains of P. aeruginosa recently isolated fro...

متن کامل

The mycobactericidal efficacy of ortho-phthalaldehyde and the comparative resistances of Mycobacterium bovis, Mycobacterium terrae, and Mycobacterium chelonae.

OBJECTIVES To assess the mycobactericidal efficacy of an agent relatively new to disinfection, ortho-phthalaldehyde (OPA) and to compare the resistances of three Mycobacterium species. Mycobacterium bovis (strain BCG) was compared with Mycobacterium chelonae and Mycobacterium terrae to investigate the feasibility of using either of the latter two species in tuberculocidal testing. M. chelonae (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Intestinal research

دوره 14 2  شماره 

صفحات  -

تاریخ انتشار 2016